跳至主要内容
临床试验/NCT01935141
NCT01935141撤回不适用

Efficacy Of Low(30 Ml) Versus Full Dose (100 Ml)Contrast CT Pulmonary Angiography Performed On 64 Multi-Detector CT In Detecting Emboli

VA Greater Los Angeles Healthcare System1 个研究点 分布在 1 个国家开始时间: 2016年1月最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
撤回
发起方
试验地点
1
主要终点
CT Image Quality Score

研究概览

简要总结

With the improvement in CT scanners and injectors, diagnostic chest CT can now be performed in less than 10 seconds. It was hypothesized that diagnostic CT pulmonary angiograms could be done with less than the usual 80-120 ml of contrast used. We have developed a method of performing diagnostic CT pulmonary angiograms with 30 ml of intravenous contrast in most patients. The long-term objective of this study is to show that there is no difference in the diagnostic efficacy of this low dose 30 ml technique when compared to the more traditional full-dose technique.

详细描述

Potential participants in the study will have been referred to the radiology section for a CTPA for a suspected pulmonary embolus. The radiologist will review the patient's record in CPRS, as is done routinely in this situation. Patients with class 3 or 4 CHF, supraventricular tachycardia, Serum Creatinine >1.5 mg/dl (>1.3 mg/dl female), history of contrast allergy, or unable to give informed consent will be excluded from both arms of the study. Patients with serum creatinine >1.28 mg/dl require referring physician approval. If the participant appears to qualify for the study then the study physician will contact the referring physician and inform him/her of the study. If the referring physician is agreeable then either the radiologist or the referring physician will approach the patient, either at the bedside or in the radiology clinic to determine if the patient is interested in participating in the study. If so, a study radiologist will begin the informed consent process. After informed consent is obtained the subject will be computer randomized to either the new low-dose or full-dose technique protocols. A total of 220 studies (110 per group) will be performed.

Multidetector CT Scan: All CT examinations will be performed on the Siemens Sensation 64-MDCT scanner. Visipaque (Iodixanol) 320 non-ionic isoosmolar contrast agent will be used in all contrast examinations followed by a subsequent injection of normal saline. An informed written consent for the injection of IV contrast will be obtained prior to all CT examinations. Safe venous access will be obtained via either an antecubital vein or a central venous line. For low dose CT pulmonary angiograms, 30 ml of IV Radio Contrast Material (RCM) will be injected at a flow rate of 5 ml/second followed by an injection of 20 ml of normal saline at 5ml/second. The region of interest (ROI) will be the superior vena cava (SVC) at the approximate level of the aortic arch. The scan will be triggered to begin at 75 Hounsfield units (HU). For Full dose CT pulmonary angiograms, 100 ml of IV RCM will be injected at a flow rate of 5ml/sec. The ROI will be the main pulmonary artery. The scan will be triggered at 120 HU. One mm contiguous axial spiral scans will be obtained from the apex of the lung through the adrenals. Reformatted 1.5 mm axial, 3 mm axial, 1.5 mm coronal and sagittal images will be obtained. All images will be uploaded to the AGFA Picture Archiving Communication System (PACS) workstation for interpretation. The costs of all CT scans and RCM will be covered by the Department of Imaging as the majority of the studies are part of routine clinical care.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Diagnostic
盲法
Single (Outcomes Assessor)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patients referred for CT pulmonary angiogram to exclude pulmonary embolus

排除标准

  • Class 3 or 4 Congestive Heart Failure
  • Supraventricular tachycardia
  • History of contrast allergy
  • Unable to give informed consent
  • Patients with serum creatinine >1.28 mg/dl without referring physician approval

研究组 & 干预措施

Low-Dose IV Contrast

Experimental

A single intravenous dose of 30 ml of Visipaque 320 non-ionic isoosmolar contrast agent will be given for each CT scan. The CT scan will be performed using a Siemens Sensation 64-MDCT scanner.

干预措施: Low-Dose IV Contrast (Procedure)

Low-Dose IV Contrast

Experimental

A single intravenous dose of 30 ml of Visipaque 320 non-ionic isoosmolar contrast agent will be given for each CT scan. The CT scan will be performed using a Siemens Sensation 64-MDCT scanner.

干预措施: Siemens Sensation 64-MDCT scanner. (Device)

Low-Dose IV Contrast

Experimental

A single intravenous dose of 30 ml of Visipaque 320 non-ionic isoosmolar contrast agent will be given for each CT scan. The CT scan will be performed using a Siemens Sensation 64-MDCT scanner.

干预措施: Visipaque 320 non-ionic isoosmolar contrast agent (Drug)

Full-Dose IV Contrast

Active Comparator

A single intravenous dose of 100ml of Visipaque 320 non-ionic isoosmolar contrast agent will be given for each CT scan. The CT scan will be performed using a Siemens Sensation 64-MDCT scanner.

干预措施: Low-Dose IV Contrast (Procedure)

Full-Dose IV Contrast

Active Comparator

A single intravenous dose of 100ml of Visipaque 320 non-ionic isoosmolar contrast agent will be given for each CT scan. The CT scan will be performed using a Siemens Sensation 64-MDCT scanner.

干预措施: Siemens Sensation 64-MDCT scanner. (Device)

Full-Dose IV Contrast

Active Comparator

A single intravenous dose of 100ml of Visipaque 320 non-ionic isoosmolar contrast agent will be given for each CT scan. The CT scan will be performed using a Siemens Sensation 64-MDCT scanner.

干预措施: Visipaque 320 non-ionic isoosmolar contrast agent (Drug)

结局指标

主要结局

CT Image Quality Score

时间窗: Within 4 weeks of the CT scan

次要结局

未报告次要终点

研究者

发起方
VA Greater Los Angeles Healthcare System
申办方类型
Fed
责任方
Principal Investigator
主要研究者

Bruce Barack

Staff Radiologist

VA Greater Los Angeles Healthcare System

研究点 (1)

Loading locations...

相似试验