A Safety and Efficacy Study to Assess OZURDEX® in Patients With Macular Oedema Secondary to Retinal Vein Occlusion (RVO)

Completed
Conditions
Macular Edema
Retinal Vein Occlusion
Interventions
Registration Number
NCT01571557
Lead Sponsor
Allergan
Brief Summary

This study will evaluate the relationship between time since onset of macular oedema symptoms and the achievement of vision gain in patients prescribed OZURDEX®. All care and diagnostic procedures provided are at the discretion of the participating physicians according to their clinical judgment and local standard of medical care.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
573
Inclusion Criteria
  • Diagnosis of macular edema following retinal vein occlusion
  • Prescribed OZURDEX®
Exclusion Criteria
  • Previous treatment with OZURDEX®

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
OZURDEX®dexamethasone 700 ug intravitreal implantOZURDEX® (dexamethasone 700 ug intravitreal implant) administered according to standard of care.
Primary Outcome Measures
NameTimeMethod
Change From Baseline in Best Corrected Visual Acuity (BCVA) in the Study EyeBaseline, Week 12

BCVA is measured in the study eye following each injection of OZURDEX® using the Snellen eye chart. BCVA measurements expressed in Snellen fractions are converted to logMAR units and the approximate Early Treatment Diabetic Retinopathy Study (ETDRS) letter score is based on the formula: approximate ETDRS letters=85+50 x log10 (Snellen fraction). The converted scores are "approximate ETDRS letters" to distinguish the scores from visual acuity measurements obtained using the ETDRS chart. One line on the EDTRS equals 5 ETDRS points. The lower the number of letters read correctly on the eye chart (lower number on the decimal scale) the worse the vision (or visual acuity). The higher the number of letters read correctly (higher number on the decimal scale), the better the vision (or visual acuity). A positive number change from baseline in the number of letters read means vision has improved and a negative number change from baseline means vision has worsened.

Secondary Outcome Measures
NameTimeMethod
Percentage of Patients With an Increase of ≥2 Lines From Baseline BCVA in the Study EyeBaseline, 48 Weeks

BCVA is measured in the study eye following each injection of OZURDEX® using the Snellen eye chart. BCVA measurements expressed in Snellen fractions are converted to logMAR units and the approximate ETDRS letter score is based on the formula: approximate ETDRS letters=85+50 x log10 (Snellen fraction). The converted scores are "approximate ETDRS letters" to distinguish the scores from visual acuity measurements obtained using the ETDRS chart. One line on the EDTRS equals 5 ETDRS points. The lower the number of letters read correctly on the eye chart (lower number on the decimal scale) the worse the vision (or visual acuity). An increase of 2 letters or more indicates an improvement in BCVA.

Percentage of Patients With an Increase of ≥3 Lines From Baseline BCVA in the Study EyeBaseline, 48 Weeks

BCVA is measured in the study eye following each injection of OZURDEX® using the Snellen eye chart. BCVA measurements expressed in Snellen fractions are converted to logMAR units and the approximate ETDRS letter score is based on the formula: approximate ETDRS letters=85+50 x log10 (Snellen fraction). The converted scores are "approximate ETDRS letters" to distinguish the scores from visual acuity measurements obtained using the ETDRS chart. One line on the EDTRS equals 5 ETDRS points. The lower the number of letters read correctly on the eye chart (lower number on the decimal scale) the worse the vision (or visual acuity). An increase of 3 letters or more indicates an improvement in BCVA.

Mean Change From Baseline in Central Retinal ThicknessBaseline, Week 24

Retinal thickness is assessed by optical coherence tomography (OCT) in the study eye. The retina is the light-sensitive part of the eye. OCT is a laser-based, noninvasive, diagnostic system providing high-resolution, three-dimensional images of the retina. A negative mean change from baseline indicates an improvement and a positive mean change from baseline indicates a worsening.