跳至主要内容
临床试验/NCT02420639
NCT02420639已完成不适用

Prospective, Interventional Study Evaluating the Feasibility and Safety of the Esophageal Cooling Device in 15 Patients Suffering From Traumatic Brain Injury and Treated With Targeted Temperature Management

Advanced Cooling Therapy, Inc., d/b/a Attune Medical1 个研究点 分布在 1 个国家目标入组 12 人开始时间: 2015年8月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
12
试验地点
1
主要终点
Time to Initiation of Temperature Management

研究概览

简要总结

The aim of this prospective, interventional study is to assess the feasibility and safety of the Esophageal Cooling Device in patients from suffering from traumatic brain injury who the treating physician is treating with targeted temperature management. Comparison of outcomes will be made to historical controls. The primary outcome is the feasibility of inducing, maintaining, and rewarming patients from targeted temperature management using the Esophageal Cooling Device (cooling rate, rewarming rate, and the percent of time within goal temperature during the goal-temperature maintenance period). Evaluation of adverse events (including cardiac arrhythmias, severe bradycardia, myocardial infarction/re-infarction, dysphagia, odynophagia, aspiration pneumonia, non-aspiration pneumonia, reflux, esophageal injury, and esophagitis) will be closely monitored during the whole period of targeted temperature management (secondary endpoint).

详细描述

Controlling patient's body temperature, and in particular, reducing body temperature in a treatment referred to as targeted temperature management, has been shown to improve outcomes for many conditions, including neonatal hypoxic ischemic encephalopathy, cardiac arrest, and traumatic brain injury. However, available modalities for inducing targeted temperature management have a number of technical, logistical, and financial barriers. The Esophageal Cooling Device is a multi-chambered silicone tube placed in the esophagus that provides a highly efficient heat transfer to or from a patient.

Traumatic brain injury (TBI) is a major cause of death and severe disability throughout the world. Current methods of traumatic brain injury treatment include reduction of brain swelling and edema, both by surgical means, as well as by reduction of temperature and avoidance of fever. Methods used to reduce temperature and control fever include surface devices, such as ice packs and water circulating blankets, and intravascular catheters, which are placed into a blood vessel.

The esophagus is in close proximity to blood flow from the heart and great vessels, and the Esophageal Cooling Device (ECD) is designed to take advantage of this heat exchange environment. The ECD's ability to decompress the stomach and avoid distention of the esophagus away from the device ensures good contact with the esophageal mucosa, and thus maximizes heat transfer from the patient. The ECD replaces the standard gastric tube which is placed in the target patient population as a routine standard of care, is made of standard medical-grade silicone, and is generally similar in size and shape to the gastric tubes currently used. Initial mathematical, animal, and human data have shown strong support for the efficacy and safety of the ECD.

The aim of this prospective, interventional study is to assess the feasibility and safety of the Esophageal Cooling Device in patients from suffering from traumatic brain injury who the treating physician is treating with targeted temperature management. Comparison of outcomes will be made to historical controls. The primary outcome is the feasibility of inducing, maintaining, and rewarming patients from targeted temperature management using the Esophageal Cooling Device (cooling rate, rewarming rate, and the percent of time within goal temperature during the goal-temperature maintenance period). Evaluation of adverse events (including cardiac arrhythmias, severe bradycardia, myocardial infarction/re-infarction, dysphagia, odynophagia, aspiration pneumonia, non-aspiration pneumonia, reflux, esophageal injury, and esophagitis) will be closely monitored during the whole period of targeted temperature management (secondary endpoint).

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Supportive Care
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient population will consist of 15 patients suffering from traumatic brain injury, in whom the treating clinician has determined that targeted temperature management will be initiated.

排除标准

  • Patients with known esophageal deformity or evidence of esophageal trauma (for example, known esophageal varices, cirrhosis, history of esophagectomy, previous swallowing disorders, achalasia, etc.).
  • Patients with known ingestion of acidic or caustic poisons within the prior 24 hours.
  • Patients with less than 40 kg of body mass.
  • Patients known to be pregnant.
  • Terminal disease or "do not resuscitate order" that could lead to early-onset therapeutic withdrawal.
  • Unstable hemodynamic conditions that could lead to multi-organ failure and early-onset death.
  • Pre-existing severe conductive disorder requiring pacing.

结局指标

主要结局

Time to Initiation of Temperature Management

时间窗: 30 days

Time to initiation of targeted temperature management, as measured from the time a decision is made to begin targeted temperature management, to the time the esophageal cooling device is in place.

次要结局

  • Composite of Performance Outcomes(36 hours)
  • Composite of Safety Outcomes(Assessed over 36 hours of treatment and up to 30 days of follow-up.)

研究者

发起方
Advanced Cooling Therapy, Inc., d/b/a Attune Medical
申办方类型
Industry
责任方
Sponsor

研究点 (1)

Loading locations...

相似试验