MedPath

Smart Watch iECG for the Detection of Cardiac Arrhythmias

Completed
Conditions
Arrhythmias, Cardiac
Atrial Fibrillation
Interventions
Device: iECG recording
Registration Number
NCT04092985
Lead Sponsor
Helios Health Institute GmbH
Brief Summary

This study aims to assess the feasibility and reliability of smart watch iECG provided by the Apple Watch/Apple iPhone for the detection of different cardiac arrhythmias. In this study, results from a 12-lead ECG will be set as the gold standard for the arrhythmia diagnosis, and results from the smart watch iECG (Apple watch/Apple iPhone application and Cardiologist's interpretations) as the index tests. The iECG tracings will be recorded simultaneously, starting and ending at the same time as the standard 12-lead ECG, using the built-in sensors of a smart watch (Apple Watch Series 4) with the ECG application.

Detailed Description

This diagnostic accuracy study is an investigator-initiated trial to evaluate the value of a smart watch-based iECG for detection of cardiac arrhythmias.

iECG tracings will be recorded simultaneously, starting and ending at the same time as the standard 12-lead ECG, using the built-in sensors of a smart watch (Apple Watch Series 4) with the market version of the ECG application (Apple Inc., California). Participants will be advised to lie down in a supine position and breathe spontaneously. All recording will be done by trained study personnel.

All iECG and 12-lead ECG recordings will be presented in PDF format as our references. Saved formats will be transferred to our Telemonitoring Center for further analysis and processing.

Results from a 12-lead ECG will be considered as the gold standard for the measurement of heart rhythms and the arrhythmia diagnosis. All 12-lead ECGs recordings will be analyzed by 2 blinded cardiologists and will be categorized as "Sinus rhythm", "High or low heart rate", "Atrial fibrillation", or "Inconclusive". Besides, cardiologists will report ECG wave's characteristics as well as any other possible diagnosis including "Superior ventricular tachycardia", "Ventricular tachycardia", "Atrial flutter", and "other types: other possible arrhythmias". In the case of uncertainties, a third cardiologist will be consulted, blinded for initial diagnoses.

The iECG recordings (test index) will be interpreted and reported in two different ways:

1. By using HealthKit Framework (Apple Watch and Apple iPhone applications): After a successful iECG recording with the Apple watch, iECGs will be transmitted by the ECG application to the iPhone. The Health App (Apple Inc., California) will receive, process and store the iECGs on the iPhone and will present one of the following results on the iPhone screen automatically: "Sinus rhythm", "High or low heart rate", "Atrial fibrillation", or "Inconclusive". Besides, the mean heart rate will be recorded, which will be automatically calculated by the Health App.

2. By cardiologist: All iECGs will be analyzed by 2 blinded cardiologists. They will report their findings in the following categorize: "Sinus rhythm", "High or low heart rate", "Atrial fibrillation", or "Inconclusive". Besides, they will report ECG wave's characteristics as well as any other possible diagnosis including "Superior ventricular tachycardia", "Ventricular tachycardia", "Atrial flutter", and "other types: other possible arrhythmias". In the case of uncertainties, a third cardiologist will be consulted, blinded for initial diagnoses.

ECG wave's characteristics: The following variables will be measured as the iECG and 12-lead ECG waves' characteristics. Three randomly chosen heartbeats will be considered to measure each wave or interval, and the mean of these 3 measurements will be used for statistical analysis.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
500
Inclusion Criteria
  • Patients aged≥22 years at the time of eligibility screening will be included.
  • Patients with known cardiac arrhythmias; i.e. AF before and after cardioversion, hemodynamically stable Bradycardias, SVT and VT during EP procedures and implants can also be included
Exclusion Criteria
  • Pregnancy

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Patients suspected with Cardiac ArrhythmiaiECG recordingiECG + 12-lead ECG recording in patients suspected with any type of cardiac arrhythmias at the time of recruitment
Primary Outcome Measures
NameTimeMethod
Level of agreement between the cardiologist's interpretations of the 12-lead ECG and the ECG App interpretation resultsBaseline
Level of agreement between the cardiologist's interpretations of the iECG and the ECG App interpretation resultsBaseline
Level of agreement between the cardiologist's interpretations of the 12-lead ECG and iECGBaseline
Secondary Outcome Measures
NameTimeMethod
Proportion of interpretable and non-interpretable iECGsBaseline
Sensitivity and specificity of screening tests for cardiac arrhythmias identification using: cardiologists interpretation of iECG (index test) and 12-lead ECGs (reference test)Baseline
Proportion of participants that remain in arrhythmia diagnosis, from the positive diagnosis from the iECG to the performed 12-lead ECGBaseline
Sensitivity and specificity of screening tests for cardiac arrhythmias identification using: ECG App interpretation results (index test) and 12-lead ECGs (reference test)Baseline

Trial Locations

Locations (1)

Andreas Bollmann

🇩🇪

Leipzig, Germany

© Copyright 2025. All Rights Reserved by MedPath