Skip to main content
Clinical Trials/NCT04450628
NCT04450628Active, not recruitingNot Applicable

Esophagogastric Junction Distensibility During Hiatal Hernia Repair

Wake Forest University Health Sciences1 site in 1 country25 target enrollmentStarted: September 28, 2020Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Active, not recruiting
Enrollment
25
Locations
1
Primary Endpoint
Change in distensibility index

Study Overview

Brief Summary

The investigators aim to ascertain the effects of hiatal hernia repair and fundoplication on the distensibility of the esophagogastric junction (EGJ) as measured by FLIP topography/impedance planimetry. The investigators also aim to assess for any correlation between values of EGJ distensibility and GERD related quality of life (QOL) and dysphagia scores.

Detailed Description

Patients referred for antireflux surgery and/or hiatal hernia repair will be considered for enrollment. Standard preoperative evaluation will include esophagogastroduodenoscopy (EGD) to assess for intraluminal pathology including esophagitis, columnar lined esophagus suggestive of Barrett's esophagus, intraluminal masses, and to measure hernia size. Patients will also undergo preoperative high resolution esophageal manometry testing with impedance as clinically indicated to evaluate esophageal motility as assessed by standardized Chicago Classification V3. Manometry will occasionally be avoided in patients with paraesophageal hernias without substantial dysphagia or those not amenable to manometry, with appropriate upper gastrointestinal radiology imaging (UGI), who will be having partial fundoplications. UGI is also a routine preoperative evaluation. Furthermore, pH testing for evaluation of acid reflux will be performed in patients without LA grade C or D esophagitis, paraesophageal hernia, or pathologic confirmation of Barrett's esophagus.

Patients appropriate for enrollment will be consented in the office setting. Preoperative baseline evaluations of symptom severity will be assessed via the GERD-HRQL survey and Mayo Dysphagia Questionnaire. Surgery will be scheduled and patients will undergo intraoperative impedance planimetry with EndoFLIP obtaining measurements of the cross-sectional area, balloon pressure, minimum diameter, compliance, length of high pressure segment, and distensibility index of the EGJ using an 8cm EndoFLIP balloon. Sequential assessments will be performed to 30ml and 40ml for up to a minute for each volume of distension. An initial baseline measurement will be obtained after establishment of pneumoperitoneum. A second measurement will occur following hiatal dissection and mobilization but prior to crural closure. Two additional measurements will be obtained after hiatal closure and after fundoplication.

No adjustment will be made to the surgical procedure based on EndoFLIP results, as the operating surgeon will not be informed of the measured values. The EndoFLIP catheters and generator will be provided by Medtronic, at no cost to the patient. Medtronic will also cover the fees associated with the EndoFLIP procedure (CPT 91040 is used).

Postoperative clinical care will proceed as per standard protocol for foregut surgery, with 1 additional office visit. Reports of postoperative symptomatology and quality of life will be performed, via GERD-HRQL and Mayo Dysphagia Questionnaire during follow up clinic appointments at 2 weeks and 6 weeks postoperative, and with additional long-term follow-up of at 6 months. Long-term follow-up will again assess for quality of life symptoms via GERD-HRQL and the Mayo Dysphagia Questionnaire. The 6 month follow-up visit is not typical practice and the patients cost for this visit will be covered by Medtronic. Per standard clinical care, recurrence of symptoms or dysphagia at any point may lead to additional postoperative testing, including UGI, EGD, pH testing, esophageal manometry, CT scan, or EndoFLIP. Postoperative GERD-HRQL and Mayo Dysphagia score results will be compared to intraoperative EndoFLIP measurements in interim and final analysis.

Study Design

Study Type
Interventional
Allocation
Na
Intervention Model
Single Group
Primary Purpose
Treatment
Masking
None (Participant, Care Provider, Investigator)

Masking Description

Surgeons will be blinded to EndoFLIP results for half of the cases, with the first 25 cases blinded and the second 25 cases with the surgeons unblinded. There will be interim analysis between the two groups' surgeries. During blinded cases no adjustment will be made to the surgical procedure based on EndoFLIP results, as the operating surgeon will not be informed of the measured values. After the first 25 cases, the surgeons will be unblinded and be able to determine goal impedance planimetry values based on patient postoperative symptom scores. In the following 25 unblinded cases, the surgeon will be able to augment the surgical intent based on EndoFLIP measurements, such as adding or removing hiatal sutures or repeating the fundoplication . Patients will be blinded to the type of procedure (i.e. surgeon blinded or unblinded).

Eligibility Criteria

Ages
18 Years to — (Adult, Older Adult)
Sex
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Patient undergoing hiatal hernia repair (types I-IV included) and fundoplication
  • Absence of spastic esophageal disorders (i.e. jackhammer esophagus, achalasia types I-III) assessed by preoperative high-resolution manometry
  • Adult patients ≥18 years
  • Elective repairs

Exclusion Criteria

  • Redo hiatal hernia repairs
  • Emergent repairs
  • Patients with contraindication to surgery or endoscopy
  • Patients with esophageal varices
  • Cases with insufficient esophageal length in which fundoplication is unable to be performed or a Collis gastroplasty is required
  • Connective tissue diseases such as scleroderma or lupus
  • Diameter measurements less than 5 mm as the EF-325N catheter is not suitable

Arms & Interventions

Hiatal Hernia Repair Patients

Experimental

Patients undergoing hiatal hernia repair (types I-IV included) and fundoplication

Intervention: EndoFLIP (Device)

Outcomes

Primary Outcomes

Change in distensibility index

Time Frame: Baseline to day 1

Distensibility index of esophagogastric junction will be measured 8cm EndoFLIP balloon at baseline and after hiatal hernia repair.

Secondary Outcomes

  • Gastroesophageal Reflux Disease Health Related Quality of Life Questionnaire (GERD-HRQL) Score(baseline, postop week 2, postop week 6, postop month 6)
  • Mayo Dysphagia Questionnaire (MDQ-30) Score(baseline, postop week 2, postop week 6, postop month 6)

Investigators

Sponsor Class
Other
Responsible Party
Sponsor

Study Sites (1)

Loading locations...

Similar Trials