BOOST: Benefit of Frequent Optimization After Cardiac Resynchronization Therapy Device Replacement

Abbott Medical Devices2 个研究点 分布在 1 个国家目标入组 17 人开始时间: 2009年6月1日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
终止
入组人数
17
试验地点
2
主要终点
Stroke Volume (SV) Measured by Aortic Velocity Time Integral (AoVTI)

研究概览

简要总结

Cardiac resynchronization therapy (CRT) has shown improvement in mortality and morbidity in patients with left ventricular systolic dysfunction and congestive heart failure. Additionally in CRT patients it has been demonstrated that optimizing paced/sensed atrioventricular (AV) and interventricular (V-V) timings leads to immediate hemodynamic benefits and further improves cardiac function. Recent studies have shown that optimal paced/sensed AV and V-V delays change over time, which raises the question of how often optimization should be repeated. Thus, frequent re-optimization of these delays might be beneficial for maintaining significant improvement of cardiac function. However, it remains to be evaluated whether timing optimization may be beneficial on patients who have received CRT for a number of years and are now having the CRT device replaced.

详细描述

  • This is a prospective, randomized, and multicenter study
  • Patients who have received a replacement St. Jude Medical(SJM) CRT device, either CRT-P or CRT-D, within the last two weeks post CRT replacement will be considered for enrollment in the study.
  • Baseline measurements will be performed at the time of enrollment.
  • Patients are followed up to 12 months post CRT replacement with data collected at 3, 6, 9 and 12 months post CRT replacement.
  • Patients will be randomized at enrollment to either Group 1 (use of SJM algorithm to optimize programming) or Group 2 ("Control").

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Parallel
主要目的
Treatment
盲法
Single (Participant)

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Patient underwent a CRT replacement within the last two weeks, triggered by either the elective replacement indicator (ERI)/end of life (EOL), or by receiving a CRT-D device as an upgrade from a CRT-P device.
  • •Patient has received an FDA approved SJM CRT device as a replacement to the old CRT device within the last two weeks.
  • •Patient has the ability to complete a 6-minute hall walk without any assistance.
  • •Patient is willing to provide written informed consent.
  • •Patient has the ability to independently comprehend and complete a QOL questionnaire.
  • •Patient is geographically stable and is willing to comply with the required follow-up schedule.

排除标准

  • •Patient had paced/sensed AV and/or V-V delay optimization using QuickOpt before CRT replacement.
  • •Patient had any paced/sensed AV and/or V-V delay optimization within 3 months before CRT replacement.
  • •Patient has an ability to walk ≥ 450 meters (≥ 1476 feet) in 6 minutes.
  • •Adequate patient's echocardiography/Doppler images will not be available.
  • •Patient is expected to receive a heart transplant during the duration of the study.
  • •Patient has an epicardial ventricular lead system (Active or Inactive).
  • •Patient has limited intrinsic atrial activity (≤ 40 bpm).
  • •Patient has persistent or permanent atrial fibrillation (AF).
  • •Patient has 2° or 3° heart block.
  • •Patient's life expectancy is less than 1 year.
  • •Patient is less than 18 years old.
  • •Patient is pregnant.
  • •Patient is on IV inotropic agents 1 month prior to CRT replacement.

研究组 & 干预措施

QuickOpt

Experimental

干预措施: QuickOpt - SJM CRT (Group 1) (Device)

Control

Active Comparator

干预措施: Control - SJM CRT (Group 2) (Device)

结局指标

主要结局

Stroke Volume (SV) Measured by Aortic Velocity Time Integral (AoVTI)

时间窗: 12 months

The BOOST study is prematurely terminated so there were no enough numbers of patients to have a meaningful measurement.

次要结局

未报告次要终点

研究者

申办方类型
Industry
责任方
Sponsor