Pinnacle Metal-on-Metal 522 Post-Market Surveillance Study
- Conditions
- Adverse Local Tissue ReactionTotal Hip ArthroplastyRevised Pinnacle Metal-on-MetalMetal IonsPinnacle Metal-on-Metal
- Interventions
- Device: Pinnacle Metal-on Metal
- Registration Number
- NCT01828801
- Lead Sponsor
- DePuy Orthopaedics
- Brief Summary
The purpose of this clinical study is to evaluate blood metal ion levels as a function of time of implantation for the Pinnacle Acetabular MoM system.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 276
-
Able to (or capable of) provide written, voluntary consent to participate in the clinical investigation
-
Is willing and able to return for all protocol defined clinic visits
-
Subject has a combination of the following implants in the study hip (unless in pre-op cohort):
- Pinnacle acetabular shell with or without Gription TM porous coating
- M-specification cobalt-chrome femoral head or aSphere M-specification cobalt-chrome femoral head
- Ultamet metal insert
- One of the following stems
i. S-ROM ii. Corail iii. Tri-Lock iv. AML v. Summit vi. Prodigy vii. C-Stem
-
Subject has high quality films available for review that were taken within 12 months of the primary surgery of the following views:
- Standing AP-Pelvis
- Standing AP-Proximal Femur (if this view is not available but the AP-Pelvis shows the entire implant and greater trochanter, that is also acceptable)
- Lauenstein Lateral Proximal Femur (Lateral-Femur)
- The subject refuses to allow their medical records to be inspected by the Sponsor, representatives of the Sponsor, the medical office staff and/or representatives from FDA
- The implanted hip components in the study hip (exclusive of cement), are not all DePuy components (unless in pre-op cohort)
- The primary procedure occurred greater than 8 (eight) years ago (unless in pre-op cohort)
- FOR PRE-OPERATIVE COHORT ONLY: the subject has a MoM contralateral hip
- FOR PRE-OPERATIVE COHORT ONLY: the subject is undergoing a revision of the Ipsilateral hip
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description 8 year post-op Pinnacle Metal-on Metal Patients that underwent a Pinnacle Metal-on-Metal (MoM) total hip replacement (THR) and at the time of enrollment, based on their date of surgery, were 8 years post-operative . Alternatively these are patients who have had their Pinnacle Metal-on-Metal hip revised but if they were not revised, would have fallen into this time point. 1 year post-op Pinnacle Metal-on Metal Patients that underwent a Pinnacle Metal-on-Metal (MoM) total hip replacement (THR) and at the time of enrollment, based on their date of surgery, were 1 year post-operative . Alternatively these are patients who have had their Pinnacle Metal-on-Metal hip revised but if they were not revised, would have fallen into this time point. 2 year post-op Pinnacle Metal-on Metal Patients that underwent a Pinnacle Metal-on-Metal (MoM) total hip replacement (THR) and at the time of enrollment, based on their date of surgery, were 2 years post-operative . Alternatively these are patients who have had their Pinnacle Metal-on-Metal hip revised but if they were not revised, would have fallen into this time point. 3 year post-op Pinnacle Metal-on Metal Patients that underwent a Pinnacle Metal-on-Metal (MoM) total hip replacement (THR) and at the time of enrollment, based on their date of surgery, were 3 years post-operative . Alternatively these are patients who have had their Pinnacle Metal-on-Metal hip revised but if they were not revised, would have fallen into this time point. 4 year post-op Pinnacle Metal-on Metal Patients that underwent a Pinnacle Metal-on-Metal (MoM) total hip replacement (THR) and at the time of enrollment, based on their date of surgery, were 4 years post-operative . Alternatively these are patients who have had their Pinnacle Metal-on-Metal hip revised but if they were not revised, would have fallen into this time point. 5 year post-op Pinnacle Metal-on Metal Patients that underwent a Pinnacle Metal-on-Metal (MoM) total hip replacement (THR) and at the time of enrollment, based on their date of surgery, were 5 years post-operative . Alternatively these are patients who have had their Pinnacle Metal-on-Metal hip revised but if they were not revised, would have fallen into this time point. 6 year post-op Pinnacle Metal-on Metal Patients that underwent a Pinnacle Metal-on-Metal (MoM) total hip replacement (THR) and at the time of enrollment, based on their date of surgery, were 6 years post-operative . Alternatively these are patients who have had their Pinnacle Metal-on-Metal hip revised but if they were not revised, would have fallen into this time point. 7 year post-op Pinnacle Metal-on Metal Patients that underwent a Pinnacle Metal-on-Metal (MoM) total hip replacement (THR) and at the time of enrollment, based on their date of surgery, were 7 years post-operative . Alternatively these are patients who have had their Pinnacle Metal-on-Metal hip revised but if they were not revised, would have fallen into this time point.
- Primary Outcome Measures
Name Time Method Change in Chromium serum ion level across time intervals Pre-operatively through 8 years To compare the chromium serum ion levels in the patient population from pre-operatively through 8 years post-operatively in a 1-way ANOVA. This is a cross-sectional study so each time interval (pre-operatively through 8 years post-operatively) will be a different cohort of patients.
Change in Chromium whole blood ion level across time intervals Pre-operatively through 8 years To compare the chromium whole blood ion levels in the patient population from pre-operatively through 8 years post-operatively in a 1-way ANOVA. This is a cross-sectional study so each time interval (pre-operatively through 8 years post-operatively) will be a different cohort of patients.
Change in Cobalt serum ion level across time intervals Pre-operatively through 8 years To compare the cobalt serum ion levels in the patient population from pre-operatively through 8 years post-operatively in a 1-way ANOVA. This is a cross-sectional study so each time interval (pre-operatively through 8 years post-operatively) will be a different cohort of patients.
Change in Cobalt whole blood ion level across time intervals Pre-operatively through 8 years To compare the cobalt whole blood ion levels in the patient population from pre-operatively through 8 years post-operatively in a 1-way ANOVA. This is a cross-sectional study so each time interval (pre-operatively through 8 years post-operatively) will be a different cohort of patients.
- Secondary Outcome Measures
Name Time Method To identify the incidence of ALTR among unrevised subjects Through 8 years post-operatively To identify the incidence of ALTR among unrevised subjects through physical examination and imaging.
Ion level change from first measurement for ALTR subjects Through 8 years post-operatively Cobalt and chromium ion levels will be compared from first measurement to the time of revision (prior to revision) or the time of last follow-up visit in the study, whichever comes first, for subjects who are diagnosed with an ALTR.
Poolability of data across stem types Pre-operatively through 8 years post-operatively Within each of the primary analyses, the poolability of data across stem types will be confirmed with a 2-way ANOVA model in which both time interval and stem type are independent variables.
Incidence of adverse local tissue reaction (ALTR) Pre-operatively through 8 years post-operatively To determine trends in the incidence of ALTR over time.
Implant survivorship Through 8 years post-operatively To determine implant survivorship, where an implant is considered to be surviving when none of the total hip replacement (THR) system components have been removed or replaced, so that the original system with metal-on-metal (MoM) articulating surfaces remains intact. Implant survivorship will be analyzed in two ways: 1) for all revisions (for any reason) and 2) for revisions due to ALTR.
Trending Through 8 years post-operatively Trends (over time since initial implant) will be evaluated for: 1) revisions (survivorship), 2) adverse events, 3) pain or functional symptoms (via Harris Hip and HOOS evaluations), 4) incidence of ALTR in unrevised subjects
Comparison of metal ion levels across subjects with vs. without ALTR Through 8 years post-operatively Cobalt and Chromium ion levels will be compared for unrevised subjects who were not diagnosed with an ALTR vs. unrevised subject who were diagnosed with an ALTR.
Ion level vs. baseline for ALTR subjects Through 8 years post-operatively To compare cobalt and chromium ion level vs. baseline for subject who are diagnosed with ALTR.
Ion levels among revised subjects Pre-operatively through 8 years post-operatively To compare cobalt and chromium ion level (prior to revision) vs. baseline for subjects who are revised.
To determine the association of adverse events with elevated ion levels Through 8 years post-operatively To investigate the association of adverse events with elevated cobalt and chromium ion levels. For each respective adverse event, to compare cobalt and chromium ion levels for subjects who have vs. subjects who have not exhibited the adverse event. For each respective adverse event category, to present summary statistics of cobalt and chromium ion levels for subjects who have vs. subjects who have not exhibited the adverse event, stratified by post-op time cohort.
Harris Hip and HOOS analysis for pain, function and total score Though 8 years post-operatively To identify the incidence of pain or functional symptoms among unrevised subjects with a Harris Hip and HOOS evaluation. To compare cobalt and chromium ion levels for unrevised subject who are exhibiting pain or functional symptoms vs. unrevised subjects who are not exhibiting pain or functional symptoms.
Patient history and demographics and association with outcomes Throughout 8 years post-operatively Patient demographic and subject history will be evaluated for association with: 1) higher metal ion levels and 2) risk of revision.
Modes and causes of implant failure Through 8 years post-operatively To evaluate modes and causes of implant failure based on an analysis of reasonably available explanted retrieved devices.
Metal ion levels and association with reason for revision Through 8 years post-operatively To compare cobalt and chromium levels across the different reasons for revision.