MedPath

Image Fusion and Calcification Raising in Trans Aortic Valve Implantation

Not Applicable
Withdrawn
Conditions
Symptomatic Aortic Stenosis
Interventions
Other: Image Fusion
Registration Number
NCT03247465
Lead Sponsor
Nantes University Hospital
Brief Summary

Aortic stenosis is one of the most common cardiology diseases. Trans aortic valve implantation (TAVI) has been developed since 2002, first to treat rejected patients from conventional surgery, then to treat high surgical risk patients and nowadays probably intermediate surgical risk patient. TAVI related complications are still recurrent and the investigators are searching a way to decrease them.

One of them could be image fusion, since it may decrease radiation exposure and contrast agent use. It may also improve valve placement position leading to decreased complications.

40 prospective and consecutive patients will be included. Participants will be divided into two groups: the 20 first included will be control group, the 20 following patients will be the fusion group. For control group TAVI procedure will be the usual one, for fusion group the procedure will be the usual one with addition of computed tomography 3D images fusion with fluoroscopy 2D images.

Main evaluation criteria will be radiation exposure, measured by dose area product (DAP). Secondary evaluation criterion will be procedural as contrast agent volume used, procedure duration, subjective usefulness of image fusion or procedure failure evaluated immediately after procedure. The investigators will also evaluated procedure induced complications as de novo pacemaker implantation, de novo left bundle branch, vascular complication, major bleeding, acute kidney failure, significant aortic regurgitation. These complications occurrence will be evaluated after 1 month follow up, during the usual following consultation.

Detailed Description

Aortic stenosis is one of the most common cardiology diseases. If untreated, symptomatic aortic stenosis rapidly leads to death. Most of the time, this disease affects old fragile people for whom conventional surgery is countered or very risky. That is why Trans aortic valve implantation has been developed since 2002, first to treat rejected patients from conventional surgery, then to treat high surgical risk patients and nowadays probably intermediate surgical risk patient. Indeed, thanks to prodigious technical and human progress, procedure induced complication have clearly decreased. But TAVI related complications are still recurrent and the investigators are searching a way to decrease them.

One of them could be image fusion, since it may decrease radiation exposure and contrast agent use correlated to acute kidney failure. It may also improve valve placement position, and the investigators know that many rhythmic (atrio-ventricular block) and valvular (significant aortic regurgitation) complications are partially due to placement mistakes. So the investigators hope that image fusion will decrease these complications.

The investigators will include 40 prospective and consecutive patients. Inclusion criterion will be all major patients admitted in Nantes CHU for transfemoral aortic valve replacement with SAPIEN® 3 valve. Exclusion criterion will be women of childbearing age without contraception, impossible written consent, judiciary protected people. After inclusion, patients will be divided into two groups: the 20 first included will be control group, the 20 following patients will be the fusion group. For control group TAVI procedure will be the usual one, for fusion group the procedure will be the usual one with addition of computed tomography 3D images fusion with fluoroscopy 2D images. The only difference during all patient medical care will be the addition of image fusion in fusion group. Before and after procedure, both groups will have the usual medical monitoring and the appropriated medical interventions to participants case.

Main evaluation criterion will be radiation exposure, measured by dose area product (DAP).

Secondary evaluation criterion will be procedural as:

* contrast agent volume used (mL),

* procedure duration (min),

* subjective usefulness of image fusion evaluated on a 0 to 3 scale

* procedure failure : death, more than one valve implantation, valve dysfunction (mean trans-valvular gradient \> 20 mmHg or moderate to severe aortic regurgitation) These criterions will be evaluated immediately after procedure.

The investigators will also evaluated procedure induced complications as:

* de novo pacemaker implantation

* de novo left bundle branch

* non minor vascular complication on VARC-2 definition

* major bleeding (BARC 3 or 5)

* acute kidney failure (AKIN 2 or 3)

* significant aortic regurgitation ≥ 2/4 These complications occurrence will be evaluated after 1 month follow up, during the usual following consultation with echocardiography.

Then differences between will be tested with appropriated statistical methods.

Recruitment & Eligibility

Status
WITHDRAWN
Sex
All
Target Recruitment
Not specified
Inclusion Criteria
  • All patients admitted in Nantes CHU for trans fermoral aortic valve replacement with SAPIEN 3® device
  • Patient who accepted to participate to the study
Read More
Exclusion Criteria
  • Impossible written consent
  • Judiciary protected people
  • Minor
  • Women of childbearing age without contraception
Read More

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Group "Fusion"Image FusionTrans aortic valve replacement with usual procedure with the addition of computed tomography 3D images and calcification raising to the usual fluoroscopy images.
Primary Outcome Measures
NameTimeMethod
Radiation exposureImmediately post procedure

Dose area product (cGy/cm2)

Secondary Outcome Measures
NameTimeMethod
Contrast productImmediately post procedure

Contrast volume (mL) used during procedure

Trial Locations

Locations (1)

Nantes University Hospital

🇫🇷

Nantes, France

© Copyright 2025. All Rights Reserved by MedPath