跳至主要内容
临床试验/NCT04230512
NCT04230512已完成不适用

Hybrid Electrical-Mechanical Pump for Vacuum Suspension of Prosthetic Sockets

VA Office of Research and Development1 个研究点 分布在 1 个国家目标入组 12 人开始时间: 2020年4月4日最近更新:
适应症
干预措施

试验速览

阶段
不适用
状态
已完成
入组人数
12
试验地点
1
主要终点
Socket-reaction moments

研究概览

简要总结

Prostheses can be suspended from the amputated limb using a variety of techniques, such as straps and suction. Suspending the prosthesis by creating a vacuum between the prosthetic socket and limb using a pump has benefits over other techniques including improved limb health and mobility. A new pump design will be tested by prosthesis users in the laboratory to verify its functionality during walking.

详细描述

Human subject testing will involve a cross-sectional, repeated measures study consisting of a single 3 hour visit wherein participants will initially stand and then continuously walk at their self-selected speed for ten minutes on a level treadmill with the prototype under two randomly presented conditions of the mechanical system: 1) fully functional, and 2) locked to restrict axial displacement. After written informed consent is obtained, information on socket comfort and mobility capability will be collected. A load-cell will be installed proximal to the prototype and in-line with the prosthesis to measure instantaneous socket-reaction moments.

研究设计

研究类型
Interventional
分配方式
Randomized
干预模型
Crossover
主要目的
Basic Science
盲法
None

入排标准

年龄范围
18 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者
否

入选标准

  • •Ability to stand quietly and walk for 10 minutes continuously without an assistive device (e.g. cane or walker) and without undue fatigue or health risks
  • •Pre-classified clinically to be at least a limited community ambulator of Medicare Functional Classification Level (K)2
  • •Residual limb in good health
  • •At least six months experience with a definitive prosthesis that utilizes vacuum assisted suspension

排除标准

  • •Pathologies aside from amputation or taking medicine that would influence walking or balance
  • •Poor prosthetic fit or poor residual limb sensation

研究组 & 干预措施

Locked

Experimental

The prototype mechanical system is locked from compressing

干预措施: Pump prototype (Other)

Unlocked

Experimental

The prototype mechanical system is free to compress normally

干预措施: Pump prototype (Other)

结局指标

主要结局

Socket-reaction moments

时间窗: Immediate

Maximum moment (torques) generated at the prosthetic socket end during walking

次要结局

  • Perceived mobility capability(Immediate)
  • Socket Comfort(Immediate)

研究者

申办方类型
Fed
责任方
Sponsor

研究点 (1)

Loading locations...