MedPath

An Instrumented Wobble Board to Present the Distribution and Center of Pressure in Dynamic Balance

Not Applicable
Completed
Conditions
Balancing Interference
Registration Number
NCT03743506
Lead Sponsor
University of Mogi das Cruzes
Brief Summary

This study quantified the displacement of the center of pressure in the computer in real time and record this data for future analyzes

Detailed Description

The wobble board is an unstable equilibrium platform, constant training on this platform generates an improvement in balance and strengthens the muscles, it is ideal for rehabilitation exercises and balance conditioning. However, these platforms do not provide quantitative data on exercises performed on it. And the force platform that provide this quantitative data is static, offering no difficulty in maintaining balance. In this way, a sensor board wobble board was developed using a conventional wobble board with a plate attached to it, between the plate and the platform are eight strain gauges sensors that are activated according to the position of the force applied on the platform, the values of the sensors are collected by software that demonstrates the point of greatest pressure on the disk and its displacement during the exercises, with this data it is possible to determine the stability of the user and observe their behavior during the exercises.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
30
Inclusion Criteria
  • Absence of musculoskeletal alteration in the lower limbs;
  • consent form signed by the volunteer;
  • with preserved cognitive
Exclusion Criteria
  • Present some impairment of the skeletal muscles of the lower limbs;
  • Present cognitive deficit.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Primary Outcome Measures
NameTimeMethod
Pressure center displacement speed15 minutes

The velocity at which the center of pressure moves during the test, divided into two steps, with three repetitions at each step, with a rest of 30 seconds at each repetition, was measured. Unit of measure: Centimeters per second (cm / s).

Secondary Outcome Measures
NameTimeMethod
Longest distance between points on X and Y axis15 minutes

It was measured at the greatest distance of the center of pressure displacement on the X and Y axis during the test, divided into two steps, with three repetitions at each stage, with a rest of 30 seconds at each repetition. Unit of measurement: Centimeters (cm).

Trial Locations

Locations (1)

Alessandro Pereira da Silva

🇧🇷

Mogi das Cruzes, São Paulo, Brazil

Alessandro Pereira da Silva