Micropulse Laser Trabeculoplasty (532nm) Versus Conventional Laser Trabeculoplasty (532nm)
Not Applicable
Completed
- Conditions
- Open Angle Glaucoma
- Interventions
- Procedure: lasertrabeculoplasty
- Registration Number
- NCT01788319
- Lead Sponsor
- Universitaire Ziekenhuizen KU Leuven
- Brief Summary
This study will investigate if micropulse laser trabeculoplasty (532nm) is as effecttive as or better than the conventional laser trabeculoplasty (532nm), it might be a new treatment strategy for glaucoma patients. It is done with a laser device that can also be used for many other ophthalmic applications, thus reducing the economic burden of treatment.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 30
Inclusion Criteria
- individuals over 18 years old
- willing to sign an informed consent and able to comply the requirements of the study
- having no other ocular diseases besides glaucoma
Exclusion Criteria
- history of ocular trauma
- intraocular surgery (except for phaco)
- pigment dispersion and exfoliation glaucoma
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description lasertrabeculoplasty lasertrabeculoplasty -
- Primary Outcome Measures
Name Time Method to compare the intraocular pressure reduction with the micropulse laser trabeculoplasty (532nm) versus the conventional laser trabeculoplasty (532nm) one year of follow-up
- Secondary Outcome Measures
Name Time Method Secondary the complication rate between the two techniques will be compared one year of follow up
Trial Locations
- Locations (1)
Department of Ophthalmology, UZLeuven
🇧🇪Leuven, Belgium