Skip to main content
Clinical Trials/NCT04626154
NCT04626154
Recruiting
Not Applicable

Validation of a Non-Invasive Device for Thoracoabdominal Asynchrony-Based Respiratory Effort Assessment in Pediatric Patients

Massachusetts General Hospital2 sites in 1 country20 target enrollmentOctober 16, 2020

Overview

Phase
Not Applicable
Intervention
Objectively monitoring thoracoabdominal asynchrony
Conditions
Respiratory Insufficiency
Sponsor
Massachusetts General Hospital
Enrollment
20
Locations
2
Primary Endpoint
Objectively determine thoracoabdominal asynchrony
Status
Recruiting
Last Updated
10 days ago

Overview

Brief Summary

The investigators hypothesize that a simple 3-point tracking device that uses motion sensors attached to the abdomen and chest of a child will provide information regarding thoracoabdominal asynchrony (TAA), a major component of respiratory distress, and ultimately help guide a clinician to initiate, escalate, de-escalate, or stop respiratory support interventions.

AIMS To determine if the TAA-monitoring device can be used to detect differences in respiratory synchrony in a manner that is clinically applicable. The investigators hope that the device will detect 1) major asynchrony events in a timely manner so as to prompt clinician intervention during future use; and 2) asynchrony events that may be less visible to the naked eye that may be precursors to more severe events.

Detailed Description

Respiratory diseases are a major global cause of morbidity and mortality in children. Of patients admitted into a pediatric intensive care unit (PICU), respiratory illnesses have been identified as the leading principal admission diagnosis in every age group, accounting for 37.9% of patients under 12 months of age and 28.5% of PICU patients across all age groups. Continuous monitoring of respiratory status is important for the guidance of respiratory support escalation and de-escalation decisions in the PICU. A clinical metric that has been suggested as a signature of breathing effort is thoracoabdominal asynchrony (TAA), the non-coincident motion of the rib cage and abdomen during breathing. A reliable, objective assessment tool for continuous monitoring of respiratory effort could allow for a more complete understanding of patients' real-time respiratory status and provide an additional indication or contraindication for the utilization of various levels of respiratory support. Limiting the use of invasive ventilatory support by early detection of respiratory distress would decrease clinical risk to patients and has the potential to decrease the cost of patient stays in the PICU. The investigators have developed a non-invasive TAA-sensing device designed for use by clinicians to indirectly quantify respiratory effort among pediatric patients (henceforth referred to as the "TAA-monitoring device"). The device utilizes motion-tracking sensors that capture data that is then processed to provide a quantitative indication of a patient's respiratory status. Given the promising yet inconclusive nature of the evidence supporting the use of TAA as an indicator of respiratory effort, clinical validation of this device is a necessary step to take to support its continued development.

Registry
clinicaltrials.gov
Start Date
October 16, 2020
End Date
June 1, 2026
Last Updated
10 days ago
Study Type
Interventional
Study Design
Parallel
Sex
All

Investigators

Responsible Party
Principal Investigator
Principal Investigator

Ryan Carroll

Staff physician

Massachusetts General Hospital

Eligibility Criteria

Inclusion Criteria

  • patients 28-days to 17-years of age
  • who have respiratory distress and those who do not have respiratory distress

Exclusion Criteria

  • Hardware, clinical care, or dermal injury that would preclude the application of TAA device

Arms & Interventions

Respiratory insufficiency or distress

Patients demonstrating respiratory insufficiency or distress.

Intervention: Objectively monitoring thoracoabdominal asynchrony

No respiratory insufficiency or distress.

Patients NOT demonstrating respiratory insufficiency or distress.

Intervention: Objectively monitoring thoracoabdominal asynchrony

Outcomes

Primary Outcomes

Objectively determine thoracoabdominal asynchrony

Time Frame: Over 30 - 7200 minutes

The investigators aim to objectively measure the frequency of asynchrony over time (minutes).

Study Sites (2)

Loading locations...

Similar Trials