Visual Outcomes After Implantation of a New Multifocal Intraocular Lens

Phase 4
Completed
Conditions
Cataract
Interventions
Device: Multifocal Intraocular Lens (RAYNER M-FLEX T TORIC IOL)
Registration Number
NCT01505816
Lead Sponsor
Hospital Oftalmologico de Brasilia
Brief Summary

This prospective nonrandomized study comprised patients with cataract, corneal astigmatism, and motivation for spectacle independence. In all cases, a Rayner M-flex® T toric Intraocular Lens will be implanted in the capsular bag. Three months postoperatively, distance, intermediate, and near visual acuities; spherical equivalent; residual refractive astigmatism; defocus curve; and contrast sensitivity will be evaluated. A patient-satisfaction and visual phenomena questionnaire will also be administered.

Detailed Description

Postoperative evaluation was performed at 3 months. The uncorrected and corrected distance visual acuity were assessed using the 100% contrast Early Treatment Diabetic Retinopathy Study chart, uncorrected intermediate visual acuity at 70 cm, and uncorrected near visual acuity at 40 cm; a binocular defocus curve was constructed using the ETDRS chart at 4 m and adding to the patient's manifest refraction +2.50 to -5.00 D sphere in 0.50 increments. The cylinder axis of the Intraocular lens (IOL) was measured at the slitlamp using the beam protractor after full mydriasis. The mean of the absolute values of degrees the intraocular lens was off axis was determined.

Contrast sensitivity was measured using the CSV-1000 HGT instrument (VectorVision, Inc.), which presents a translucent chart divided into 4 cycles with spatial frequencies of 3, 6, 12 and 18 cycles per degree. The background illumination of the translucent chart does not depend on room lighting. All measurements were obtained under mesopic (5 cd/m2) and photopic (85 cd/m2) conditions. The examinations were performed unilaterally at a distance of 2.5 m with Best-corrected visual acuity (BCVA) and an undilated pupil. All measurements were performed under the same conditions.

Patient satisfaction and quality of life were assessed by a simple questionnaire. Patients were interviewed 3 months postoperative. Patients were asked about visual disturbances, visual lifestyle activities, spectacle use, and satisfaction with the procedure.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
40
Inclusion Criteria
  • Cataract
  • Any race
  • Either gender
  • Diagnosis of cataracts both eyes
  • Pre-existing physical conditions that could skew visual results, such as Diabetes, Retinal detachment, Macular degeneration, or Cancer
  • Subjects must have > 1.00 diopter of astigmatism
Exclusion Criteria
  • Central endothelial cell count less than 2000 cells/mm2 glaucoma or intraocular pressure greater than 21 mmHg amblyopia
  • Retinal abnormalities
  • Diabetes mellitus steroid or immunosuppressive treatment
  • Connective tissue diseases

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
ToricMultifocal Intraocular Lens (RAYNER M-FLEX T TORIC IOL)Multifocal Toric IOL implantation
Primary Outcome Measures
NameTimeMethod
Visual Performance After Implantation of a Toric Multifocal Refractive Intraocular Lens3 months postoperative

Postoperative evaluation will be performed at 3 months. The uncorrected distance visual acuity (UDVA) and corrected distance visual acuity (CDVA) will be assessed using the 100% contrast ETDRS chart; a binocular defocus curve will be constructed using the ETDRS chart at 4 m.

Secondary Outcome Measures
NameTimeMethod
Contrast sensitivity3 months

Contrast sensitivity will be measured using the CSV-1000 HGT instrument (VectorVision, Inc.), which presents a translucent chart divided into 4 cycles with spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd). The background illumination of the translucent chart does not depend on room lighting. All measurements will be obtained under mesopic (5 cd/m2) and photopic (85 cd/m2) conditions. The examinations will be performed unilaterally at a distance of 2.5 m with BCVA and an undilated pupil. All measurements will be performed under the same conditions.

Patient satisfaction3 months

Patient satisfaction and quality of life will be assessed by a simple questionnaire. Patients will be interviewed 3 months postoperative. Patients will be asked about visual disturbances, visual lifestyle activities, spectacle use, and satisfaction with the procedure.