Microanalysis of Changes in 3D Geometry of Orthodontic Mini-implants
- Conditions
- MalocclusionsMalocclusion, Angle Class IMalocclusion, Angle Class II
- Registration Number
- NCT06743360
- Lead Sponsor
- Pomeranian Medical University Szczecin
- Brief Summary
The orthodontic mini-implants used in the study are temporary screws inserted into the bone to provide anchorage for challenging tooth movements that could not be carried out using the patient's own teeth. They are made of a medical grade titanium alloy (Ti6Al4Va), with a length of 8 mm and a diameter of 1.3 mm. After the completion of the treatment phase requiring specific anchorage, they are removed and disposed of as a medical waste.
The insertion of the mini-screw is conditioned by the individual treatment plan and the treatment protocol would not differ from the standard treatment.
The aim of the project is to analyze changes in the macrogeometry and wear of the surfaces of retrieved orthodontic micro-implants after their clinical use. Upon completion of clinical tasks, the mini-screws will be removed and retrieved for laboratory phase of the study. The laboratory phase will consist of: microscopic and profilometric examinations, as well as scanning before insertion and after removal of the mini-implants, and a clinical phase: the use of previously scanned and sterilized mini-implants in patients participating in the study.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- ACTIVE_NOT_RECRUITING
- Sex
- All
- Target Recruitment
- 20
- Adult patient in the active phase of orthodontic treatment with a fixed orthodontic appliance.
- The individual treatment plan involving tooth movements that require anchorage reinforcement: asymmetric intrusion, space closure through mesialization or distalization.
- Clinical indications and the possibility of placing a mini-implant in the interradicular space of the maxillary/mandibular alveolar bone (possibility of using the AbsoAnchor SH1312-08 mini-implant).
- Informed consent of the patient.
- Individualized treatment plan involving the use of a mini-implant different from the one used in the study.
- Lack of consent for participation in the study.
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Geometric change 6 months Changes of mini-implant geomtery in micrometers
- Secondary Outcome Measures
Name Time Method Surface analysis 6 months Analysis of irregularities and wear pattern of removed mini-implant
Related Research Topics
Explore scientific publications, clinical data analysis, treatment approaches, and expert-compiled information related to the mechanisms and outcomes of this trial. Click any topic for comprehensive research insights.
Trial Locations
- Locations (2)
Private Dental Practice "Morze Usmiechu"
🇵🇱Swinoujscie, Zachodniopomorskie, Poland
Department of Interdisciplinary Dentistry
🇵🇱Szczecin, Zachodniopomorskie, Poland