The Biological Effects of Commercial Orthodontic Miniscrews on the Oral Investing Tissue
试验速览
- 阶段
- 不适用
- 入组人数
- 10
- 主要终点
- cytotoxicity of orthodontic miniscrew implant
研究概览
简要总结
The use of miniscrew implants as an anchorage device in orthodontics has gained a widespread acceptance in recent years. There prevailed use has been attributed to its ease in insertion and removal at a relatively low cost with no need to wait for a long time between miniscrew insertion and force application. In this regard; clinical studies have suggested that miniscrew implants may provide stable anchorage during the orthodontic treatment without requiring patient cooperation. These studies proved many successful applications in orthodontics involving; retraction of anterior teeth, correction of open bites, distalization, mesialization, and intrusion of teeth
详细描述
The use of miniscrew implants as an anchorage device in orthodontics has gained a widespread acceptance in recent years. There prevailed use has been attributed to its ease in insertion and removal at a relatively low cost with no need to wait for a long time between miniscrew insertion and force application. In this regard; clinical studies have suggested that miniscrew implants may provide stable anchorage during the orthodontic treatment without requiring patient cooperation. These studies proved many successful applications in orthodontics involving; retraction of anterior teeth, correction of open bites, distalization, mesialization, and intrusion of teeth.
In dentistry, various materials are used in implant systems. The implant material must be nontoxic, biocompatible, mechanically sufficient, and having high tension and corrosion resistance. Commercially pure titanium (cp Ti) is the most used material in prosthetic implants because of its; high biocompatibility, high corrosion resistance in body fluids, not allergic, high specific strength, and low elastic modulus when compared with other metallic biomaterials.
On the other hand, orthodontic miniscrew implants are smaller than conventional prosthetic implants and should resist high orthodontic loads. These factors contribute to the possible fracture of cp Ti miniscrew implants during placement, use, and removal. To avoid such fracture, Ti alloy implants, composed with aluminum (6Al) and vanadium (4V), (Ti-6Al-4V), for adding strength and fatigue resistance than cp Ti, are required. Unfortunately, this alloy has a low corrosion resistance and can result in corrosion of the orthodontic miniscrew implants in body fluids.
Any metal or alloy implanted in the human body is a potential source of toxicity. In an oral envelope, miniscrew implants are exposed to a number of potentially destructive physical and chemical agents. Evaluation the potential of conventional dental implants to release metallic ions into the body have been done. However, little attention has been given to metallic ion released from orthodontic miniscrew implant systems and the potential toxicity of these released metal on oral tissues. The concern about this has been limited to orthodontic brackets and wires.
One of the studies concerned with the biocompatibility of different metals used in vivo of different fixed orthodontic appliances and evaluating the presence of metal ions in oral mucosa cells, their potential cytotoxicity, and genotoxic effects. This study concluded that nickel and cobalt metals released from fixed orthodontic appliances could induce DNA damage in oral mucosa cells.
研究设计
- 研究类型
- Interventional
- 分配方式
- Na
- 干预模型
- Single Group
- 主要目的
- Treatment
- 盲法
- None
入排标准
- 年龄范围
- 14 Years 至 18 Years(Child, Adult)
- 性别
- Female
- 接受健康志愿者
- 是
入选标准
- •The patients will be included in this study if they have the following:
- •All cases indicated for bilateral extraction of maxillary first premolar and retraction of canine into the extraction space.
- •Age range from 14 to 18 years.
- •Full set of permanent teeth (the third molars are not considered).
- •No previous orthodontic or orthognathic surgery treatment.
- •Good oral and general health.
- •All teeth should be caries-free.
- •All teeth should be free from any metallic restorations.
排除标准
- •The patients will be excluded from the study if they have the following:
- •History of serious medical problems or taking systemic medication which could affect orthodontic treatment.
- •History of serious dental problems (endodontic treatment, apicectomy, or any other dental problems) which could affect orthodontic treatment.
研究组 & 干预措施
Extraction cases
patients receive Tomas orthodontic miniscrew implant as a mean of anchorage augmentation
干预措施: Tomas® Anchorage System - DENTAURUM (Device)
结局指标
主要结局
cytotoxicity of orthodontic miniscrew implant
时间窗: 4 months after initiation of the orthodontic canine retraction
Time dependent change in the percentage (%) of dead cells in series of swab samples harvested from area around orthodontic miniscrew implant.
次要结局
- Metal release of orthodontic miniscrew implant(4 months after initiation of the orthodontic canine retraction)
- surface changes of orthodontic miniscrew implants(4 months after initiation of the orthodontic canine retraction)
研究者
Ahmed S.M. Ammar
Assistant lecturer
Al-Azhar University