South American Abdominal Stent Graft Trial
- Conditions
- Abdominal Aortic Aneurysm
- Interventions
- Device: Ovation Abdominal Stent Graft System
- Registration Number
- NCT01082185
- Lead Sponsor
- TriVascular, Inc.
- Brief Summary
A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System
- Detailed Description
This study is a prospective, non-randomized multi-center clinical evaluation of the safety and performance of the TriVascular Modular Abdominal Stent Graft System when used in the treatment of subjects with abdominal aortic aneurysms (AAA).
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 20
-
Patient is > 18 years of age
-
Patients who are male or non-pregnant female (females of child bearing potential must have a negative pregnancy test prior to enrollment into the study)
-
Patient has signed an Ethics Committee approved Informed Consent Form
-
Patient is considered by the treating physician to be a candidate for elective open surgical repair of the AAA (i.e., category I, II, or III per American Society of Anesthesiology (ASA) classification; refer to Appendix III: ASA Classification System). ASA category IV patients may be enrolled provided their life expectancy is greater than 1 year.
-
Patient has an infrarenal abdominal aortic aneurysm that meets at least one of the following:
- Abdominal aortic aneurysm >5.0 cm in diameter,
- Aneurysm that has increased in size by 0.5 cm in last 6 months,
- Maximum diameter of aneurysm exceeds 1.5 times the transverse dimension of an adjacent normal aortic segment.
-
Patient has a patent iliac or femoral arteries that allow endovascular access with the TriVascular Ovation Abdominal Stent Graft System.
-
Patient has a suitable non-aneurysmal proximal aortic neck length of ≥ 7 mm inferior to the most distal renal artery ostium.
-
Patient has a suitable non-aneurysmal distal iliac artery length (seal zone) of ≥ 10 mm. The resultant repair should preserve patency in at least one hypogastric artery.
-
Patient has a suitable non-aneurysmal proximal aortic neck luminal diameter between 16 and 30 mm.
-
Patient has a suitable non-aneurysmal distal iliac luminal diameter between 8 and 20 mm.
-
Patient meets the following anatomic criteria: the distance from the most distal renal artery to most superior internal iliac artery measurement is at least 13 cm.
-
Patient has juxtarenal aortic neck angulation ≤ 60º if proximal neck is ≥ 10 mm and ≤ 45 if proximal neck is <10 mm.
-
Patient must be able and willing to comply with all required follow-up exams.
- Patient has a dissecting aneurysm.
- Patient has an acutely ruptured aneurysm.
- Patient has an acute vascular injury.
- Patient has need for emergent surgery.
- Patient has a known thoracic aortic aneurysm or dissection.
- Patient has a mycotic aneurysm or has an active systemic infection..
- Patient has unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina, or onset of prolonged angina)
- Patient has had a myocardial infarction (MI) and/or stroke (CVA) within the past 6 months.
- Patient has a major surgical or interventional procedure planned ≤ 30 days of the AAA repair.
- Patient has history of connective tissue disease (e.g., Marfan's or Ehler's-Danlos syndrome).
- Patient has history of bleeding disorders or refuses blood transfusions.
- Patient has dialysis dependent renal failure or baseline serum creatinine level >2.0 mg/dl.
- Patient has a known hypersensitivity or contraindication to anticoagulation or contrast media that is not amenable to pre-treatment.
- Patient has a known allergy or intolerance to polytetrafluoroethylene (PTFE), PEG-based polymers, fluorinated ethylene-propylene (FEP) or nitinol.
- Patient has a body habitus that would inhibit X-ray visualization of the aorta
- Patient has a limited life expectancy of less than 1 year
- Patient is currently participating in an investigational device or drug clinical trial.
- Patient has other medical, social or psychological conditions that, in the opinion of the investigator, preclude them from receiving the pre-treatment, required treatment, and post-treatment procedures and evaluations.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Ovation Abdominal Stent Graft System Ovation Abdominal Stent Graft System Endovascular implant of Abdominal Aortic Aneurysm Stent Graft
- Primary Outcome Measures
Name Time Method A Clinical Study to Evaluate the Safety and Performance of the TriVascular Ovation Abdominal Stent Graft System 30-Days
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Pontificia Universidad Catolica de Chile
🇨🇱Santiago, Chile