Skip to main content
Clinical Trials/NCT05586893
NCT05586893CompletedNot Applicable

Skin Temperature Behavior by Infrared Thermography After Application of Electroacupuncture and Acupuncture

University of Sao Paulo0 sites54 target enrollmentStarted: January 1, 2015Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Enrollment
54
Primary Endpoint
Skin temperature

Study Overview

Brief Summary

Objective: Evaluating the behavior of skin temperature through infrared thermography after application of acupuncture and electroacupuncture in Weizhong (B40) and Kunlun (B60) acupunctures points. Methods: A single-blind randomized clinical trial was performed with 54 participants of both sexes, mean of 21.88±2.53 years, randomized into three groups (n=18): electroacupuncture (EAG), acupuncture (AG) and control (CG). The application was bilateral in the acupoints (B60 and B40), for 20 minutes. The skin temperature of the lower limbs was measured at the following times: before application, 10 minutes of application, 20 minutes of application and 10 minutes after needle removal.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Parallel
Primary Purpose
Treatment
Masking
Single (Outcomes Assessor)

Eligibility Criteria

Ages
18 Years to 30 Years (Adult)
Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • •Both sexes;
  • •Aged between 18-30 years;
  • •Good general health;

Exclusion Criteria

  • •Pregnant women;
  • •Hemophiliacs;
  • •Patients with severe cardiovascular diseases.

Arms & Interventions

Electroacupuncture

Experimental

The acupuncture electrical stimulation was performed by the EL 608 electroacupuncture device (NKL, Brusque - SC, Brazil, ANVISA 80191680002). For the stimulation of the acupuncture points, we selected a biphasic wave, 2 HZ of frequency, 6 mA of wavelength, and 5 seconds at resting time. The total stimulation time was 20 minutes.

Intervention: Acupuncture therapy and Electroacupuncture (Device)

Acupuncture therapy

Experimental

The acupuncture points were bilaterally punctured by a stainless steel acupuncture needle (length 30mm x diameter 0.25) (Dongbang, Boryeong, Chungnam- Korea). We used the following Bladder acupuncture points, Weizong (B40) in the middle of the popliteal fossa and Kunlun (B60) located in a depression between the lateral malleolus and the Achilles tendon. The subjects were instructed to report the "De Qi" perception (paresthesia or numbness) that was the advice to the researchers that the point was right punctured. After the De qi was reported, the needle remained in the acupuncture point for 20 minutes and was rotated three times more for the preservation of the effect. During this time, all subjects remained in the supine laying down position on the stretcher.

Intervention: Acupuncture therapy and Electroacupuncture (Device)

Control Group

No Intervention

Infrared images were captured at the first assessment (P0), 10 minutes later (P10), 20 minutes later (P20) and 30 minutes after the first assessment (P30). All analyzes were performed using QuickReport software, version 1.2 (FLIR Systems). No application of interventions between assessments.

Outcomes

Primary Outcomes

Skin temperature

Time Frame: 30 minutes after the first assessment (P30)

Skin temperature was evaluated by infrared thermography using a thermal camera, brand FLIR® Systems (T300, Wilsonville, OR, USA), and accuracy of up to 0.05º C, with emissivity of 0.98 being established and the instrument stabilized for 10 minutes before the exam. Three infrared images were captured in sequence at a distance of 100 cm from the individual, in order to allow the framing of the evaluated limb \[20\].

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor Class
Other
Responsible Party
Principal Investigator
Principal Investigator

Elaine Caldeira de Oliveira Guirro

PhD Elaine Caldeiro de Oliveira Guirro - Professor

University of Sao Paulo