Thermoregulatory Reactions of Medical Workers Who Use Personal Protective Equipment From Biological Hazards
- Conditions
- Overheating
- Interventions
- Other: Personal protective equipment from biological hazard
- Registration Number
- NCT05091515
- Lead Sponsor
- Federal State Budgetary Scientific Institution "Izmerov Research Institute of Occupational Health"
- Brief Summary
This research will provide data on thermal condition, functional status and working conditions of medical workers who use personal protective equipment from biological hazards. Acquired data will be used to define acceptable period of use for these protective costumes.
- Detailed Description
This research will recruit 14-20 volunteers. During 8 hours each subject will perform their work using protective costume. Heart rate, electrocardiogram, oxygenation, skin and air temperature under costume and hygrometric data will be registered. Also there will be questionnaires for volunteers for subjective assessment of thermal and moisture sensations and assessment of working conditions.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 25
- healthy individuals (based on medical screening)
- endocrinological diseases and disorders
- health deviations at the time of the study
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Health workers Personal protective equipment from biological hazard Medical personnel: doctors, nurses.
- Primary Outcome Measures
Name Time Method Skin thermometry 8 hours DS1923-F5 Thermochron iButtons ("MaximIntegratedProducts, Inc", USA)
Hygrometry under costume 8 hours DS1923-F5 Thermochron iButtons ("MaximIntegratedProducts, Inc", USA)
Blood pressure 8 hours Electrocardiographic system "Poly-Specter-SM" (LLC "Neurosoft", Russia)
Electrocardiography 8 hours Electrocardiographic system "Poly-Specter-SM" (LLC "Neurosoft", Russia), all parameters.
Heart rate 8 hours Electrocardiographic system "Poly-Specter-SM" (LLC "Neurosoft", Russia)
Breathing rate 8 hours Electrocardiographic system "Poly-Specter-SM" (LLC "Neurosoft", Russia)
Air thermometry and hygrometry 8 hours "METEOSCOP-M" (LLC "NTM-Zashchita", Russia)
- Secondary Outcome Measures
Name Time Method Oxygenation 8 hours Pulse oximeter MD300C2 ("Choicemmed", China)
Trial Locations
- Locations (1)
Federal State Budgetary Scientific Institution Izmerov Research Institute of Occupational Health
🇷🇺Moscow, Russian Federation