MedPath

Corrected Carotid Flow Time for Predicting Spinal Anesthesia-induced Hypotension

Not yet recruiting
Conditions
Hypotension
Registration Number
NCT06905535
Lead Sponsor
Selcuk University
Brief Summary

Spinal anaesthesia is a standard technique frequently preferred for caesarean section. However, spinal anaesthesia-induced hypotension remains a critical problem causing undesirable maternal symptoms such as nausea, vomiting and dyspnoea and adverse consequences for umbilical acidosis and the fetus. One of the reasons aggravating hypotension is aortocaval compression of the growing uterus and consequent decrease in preload and stroke volume . Therefore, left lateral tilt position is recommended in pregnant women after the 20th gestational week to prevent supine hypotension. This position decreases uterine compression on the vena cava and increases venous return to the heart and thus stroke volume. Recently, carotid artery Doppler has been used to assess stroke volume. Many studies have shown that carotid corrected flow time increases significantly after expansion of intravascular volume in hypovolaemic patients . In one study, it was reported that the change in carotid artery blood flow time induced by passive leg raising predicts fluid sensitivity in critically ill patients. It has been reported that changes in carotid artery blood flow time against hemodynamic interventions (such as Trendelenburg position) reflect maternal hypovolemic status and distinguish hypovolemic patients with a higher risk of spinal anesthesia-related hypotension. The investigators also think that the left lateral tilt position may increase the corrected carotid flow time by affecting hemodynamics and may differentiate the patient with a high risk of hypotension.

Detailed Description

Patients undergoing elective cesarean section under spinal anesthesia will be included in the study. Carotid corrected flow time will be measured by Doppler ultrasonography in the supine and left lateral tilt (15°) positions before spinal anesthesia. Flow time will be measured using pulse Doppler waveforms in the long axis of the right common carotid artery. The measured flow time will be calculated as "corrected flow time" using the following Wodey formula; Carotid corrected flow time = measured flow time + \[1.29 (Heart rate - 60)\].

After standard monitoring (Electrocardiography, peripheral oxygen saturation, noninvasive blood pressure measurement), routine spinal anesthesia will be performed without any study-specific changes. The noninvasive blood pressure value measured before spinal anesthesia will be taken as the baseline value and a decrease of 20% or more in this value or a decrease in systolic blood pressure below 100 mmHg will be considered as "spinal anesthesia induced hypotension". Patients will be divided into those who develop spinal anesthesia-induced hypotension and those who do not develop spinal anesthesia-induced hypotension after spinal anesthesia and carotid corrected flow times will be compared between both groups.

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
Female
Target Recruitment
50
Inclusion Criteria
  • Full-term pregnancy
  • physical status II of American Society of Anesthesiologists
Exclusion Criteria
  • emergency cesarean section,
  • cesarean under general anesthesia
  • gestational Diabetes Mellitus
  • gestational Hypertension
  • preeclampsia,
  • cardiovascular disease
  • cerebrovascular disease
  • chronic kidney disease disease

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
predictive value of the carotid flow time alteration10-15 minute

rate of prediction

Secondary Outcome Measures
NameTimeMethod
© Copyright 2025. All Rights Reserved by MedPath