MedPath

SeizEAR Safety Study

Not Applicable
Conditions
Epilepsy
Registration Number
NCT07088835
Lead Sponsor
Icahn School of Medicine at Mount Sinai
Brief Summary

Determine the safety and feasibility of an in-ear device to measure seizures or suspected seizures compared to the standard scalp-based electroencephalogram (EEG). The study team anticipates enrolling five healthy participants through meeting announcements and a research email list serv in the Neurology Dept. Based on the appropriate positive initial test of healthy individuals, test the in-ear device on 10 participants with seizures or suspected seizures scheduled for a clinical scalp EEG test.

Detailed Description

SeizEAR aims to develop an in-ear device for the detection, diagnosis, and management of seizures/epilepsy. In the United States, an estimated 1 in 26 people will develop epilepsy within a lifetime, with 60% of all seizures originating in the temporal region of the brain. Electroencephalogram (EEG) is currently the gold standard for seizure detection, measuring electrical activity of the brain via numerous electrodes placed on the scalp. The demand for EEG has been steadily increasing given its higher accessibility and ability to result in substantial changes to patient management. In particular, pre-surgical evaluation of seizure was studied in the ambulatory setting, with good post-resection outcomes in selected patients with unilateral temporal lobe epilepsy. The EEG technology requires substantial technician training, can lead to patient discomfort, and still incurs high patient costs (roughly 500-3,000$ per order). Furthermore, current EEG interpretation can be complicated by high rates of false detection and poor sensitivity, as signals may be impeded by scalp conditions, the use of hair products, and other concomitant medical devices. SeizEAR will offer a technician-free, easy to use, comfortable, and cost-effective alternative to seizure monitoring. Intra-ear monitoring has been shown to permit real-time detection of seizure activity and allow for prolonged monitoring of abnormal (inter-ictal) discharges. Intra-ear monitoring is particularly suitable for temporal lobe epilepsy, given the proximity of the ear canal to the temporal lobe of the brain. Prior studies have demonstrated that intra-ear monitoring of temporal brain activity can reliably detect temporal lobe seizures with the added benefit of limiting ocular artifact, a common confounder of more traditional scalp EEG. Collaborating with the industry partner, Starkey Hearing Technologies, the researchers aim to prototype SeizEAR with two electrodes targeting the temporal lobe, wired to a signal processor/box. The objective will be to demonstrate the safety and efficacy of a first-generation SeizEAR device to monitor brain waves in healthy controls and participants with seizures or suspected temporal lobe seizures scheduled for a clinical EEG. Long term, the goal will be to validate the clinical efficacy of SeizEAR in detecting seizures

Recruitment & Eligibility

Status
ENROLLING_BY_INVITATION
Sex
All
Target Recruitment
15
Inclusion Criteria
  • Age: > 18 and <70
  • No History of Seizures or seizure-like activity based on self-report
  • Normal parameters for vitals, afebrile, blood pressure.
  • Able to read and write English
  • Capable of providing informed consent
Exclusion Criteria
  • History of seizures or seizure-like activity based on self-assessment
  • Any major health conditions based upon self-report
  • Concurrent participation in another investigational protocol.
  • A history of skin sensitivity, or rash on the head, neck or ears.
  • A history of silver allergy.
  • Treatment for an ear infection in the previous four-week period
  • Medications that would be contraindicated to participate in the study that would interfere with the EEG Testing

Phase 3 Inclusion/Exclusion Criteria: Participants with Seizures or Suspected Temporal Lobe Seizures

Inclusion Criteria:

  • Age > 18 and < 70
  • Individuals scheduled for clinical EEG for seizures or suspected temporal lobe seizures documented by a neurologist
  • Stable Health Conditions based upon the principal investigator's opinion
  • Normal parameters for vitals, afebrile, blood pressure
  • Able to read and write English
  • Capable of providing informed consent.

Exclusion Criteria:

  • Any major issues with the skull or ear that would interfere with the EEG testing.
  • A history of skin sensitivity, or rash on the head, neck or ears
  • A history of silver allergy.
  • Treatment for an ear infection in the previous four-week period.
  • Concurrent participation in another investigational protocol
  • Any psychiatric disorder (i.e. uncontrolled depression, mood disorders, cognitive impairment, schizophrenia), that complicate measurement of changes associated with the EEG testing.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SEQUENTIAL
Primary Outcome Measures
NameTimeMethod
F1 scoreat week 16

The Device F1 Score is a metric used to evaluate the performance of the ear-EEG device in detecting seizures. It is the harmonic mean of precision and recall, providing a balance between these two metrics. Precision is the proportion of true positive (TP) predictions out of all positive predictions (TP + FP), while recall (or sensitivity) is the proportion of true positive (TP) predictions out of all actual seizure events. The F1 Score ranges from 0 to 1, with higher scores indicating better performance in accurately detecting seizures. The performance of ear-EEG will be measured by the device F1 score per 24 hours accordingly.

Positive predictive value (PPV)at week 16

The Device Positive Predictive Value (PPV) is calculated by dividing the number of true positives (TP) by the total number of positive test results (TP + FP), where FP represents false positives. PPV measures the accuracy of the ear-EEG device in predicting seizures, indicating the likelihood that a positive prediction made by the device is a true seizure event. The PPV ranges from 0 to 1, with higher values indicating better accuracy in predicting seizures. The performance of ear-EEG will be measured by the positive predictive value (PPV) per 24 hours accordingly.

False detection rateat week 16

The Device False Detection Rate is a metric used to evaluate the performance of the ear-EEG device in terms of false positives. It is calculated by dividing the number of false positives (FP) by the total number of test results (TP + FP + FN), where TP represents true positives and FN represents false negatives. The false detection rate is typically expressed as the number of false positive predictions per 24 hours. Lower values indicate better performance, with fewer false alarms generated by the device.. The performance of ear-EEG will be measured by false detection rate per 24 hours accordingly.

Comfort Rating Scaleat week 16

The Comfort Rating Scale is a 6-item questionnaire that asks participants about their comfort with the device. Responses are on a 5-point Likert scale ranging from 0 (not comfortable at all) to 5 (completely comfortable). The items assessed include tightness, weight, security, softness, overall comfort, and overall fit of the device in the ear. Total scores range from 0 to 30, with higher scores indicating greater comfort.

Sensitivityat week 16

The sensitivity of ear-EEG will be measured by sensitivity the percentage of ear-EEG predictions that overlap with conventional EEG annotations for at least 1 second per 24 hours accordingly. The ear-EEG annotations will be considered as predictions and the conventional EEG annotations as the truth. Any prediction was deemed true if they overlap at least 1 second with the truth. All seizure annotations were either true positive (TP), false positive (FP), or false negative (FN).

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Icahn School of Medicine at Mount Sinai

🇺🇸

New York, New York, United States

Icahn School of Medicine at Mount Sinai
🇺🇸New York, New York, United States

MedPath

Empowering clinical research with data-driven insights and AI-powered tools.

© 2025 MedPath, Inc. All rights reserved.