MedPath

Exploration of Optical Coherence Tomography-Guided Transbronchial Biopsy in Peripheral Pulmonary Lesions

Recruiting
Conditions
Lung Neoplasm
Registration Number
NCT06419114
Lead Sponsor
Sichuan Provincial People's Hospital
Brief Summary

In this prospective analysis, investigators collected and evaluated data from patients who underwent TBB at the Respiratory Endoscopy Center of Sichuan Provincial People's Hospital. The procedures utilized a novel approach combining OCT with R-EBUS for guidance. Eligibility for participation was determined based on established guidelines for the application of diagnostic flexible bronchoscopy in adults.

The admission criteria of this study were as followed: (1) voluntary participation and written informed consent signed, (2) age ≥ 18 years old, (3) the platelets count and PT, APTT tests were normal, (4) normal ECG, (5) found PPL's by chest computed tomography (CT) within 2 weeks and (6) could not detect the lesions through routine diagnostic bronchoscopy. The exclusion criteria of this study were as followed: (1) patients with contraindication of bronchoscopy (such as respiratory failure and acute cardio-cerebrovascular events), (2) patients who refuse biopsy because of physical reasons or personal wishes, (3) patients with the objective reasons (such as abundant blood supply around the lesion) who could not complete the biopsy, (4) patients who are participating in other clinical studies, (5) patients with poor compliance who are believed by the researchers to be unable to cooperate for the completion of the examination and follow-up, and (6) women who were pregnant.

R-EBUS and OCT In this study, all procedures were conducted using a standardized flexible bronchoscopy (Olympus, Japan) featuring an outer diameter of 4.2mm. R-EBUS system (Olympus, Japan) incorporated an ultra-thin radial ultrasonic probe (Olympus UM-S20-17S), which measures merely 1.4mm in diameter. The OCT (Yongshida Medical Technology, Guangdong, China) probe is a cylindrical catheter, 1.7mm in diameter and 150cm in length. Placing the probe through the working channel of bronchoscope for real time dynamic scanning of lesions.

Research Process In this study, the entirety of the procedures was performed by the same respiratory physician with 5 years of experience in respiratory endoscopic diagnosis and treatment, including preoperative evaluation, preparation, lesion localization and biopsy. The respiratory physician had examined the bilateral airways with flexible bronchoscopy after the completion of preoperative anesthesia and found no lesions. The subsequent step involved the precise placement of the OCT probe, guided by prior CT scan results. This stage was critical for marking the lesion, determining its nature (benign or malignant), and, in cases of malignancy, identifying its pathological classification. In instances where the OCT failed to identify any lesion, the R-EBUS was employed to facilitate lesion localization and biopsy. Conversely, when PPLs was detected via OCT, R-EBUS was additionally utilized to corroborate the PPLs localization and to assist in completing the biopsy procedure. For cases where OCT localization failed, R-EBUS would be used. After successful confirmation with R-EBUS, an attempt was made again to insert the OCT probe and completed biopsy. Rapid On-Site Evaluation (ROSE) was employed for the assessment of biopsy specimens. A total of five specimens were collected from each lesion and subjected to ROSE. In scenarios where ROSE provided a definitive diagnosis, no additional biopsies were deemed necessary. Conversely, in instances where ROSE yielded non-definitive results, further biopsy samples were obtained. All biopsy specimens were preserved in 10% formalin, preparing them for detailed histopathological analysis. The ultimate pathological diagnoses were determined based on the reports issued by the pathology department.

In this study, the demographics of all patients were documented, including age, gender, and smoking history. Additionally, detailed clinical parameters, such as the location and size of the lesions, airway grades (ranging from 0 to 24) that the PPLs located, location time of OCT and the number of specimens, were systematically recorded. investigators also conducted extensive follow-up to track histopathological outcomes, whether from surgical biopsies, CT-guided percutaneous transthoracic needle biopsies, or other diagnostic avenues, including chest CT performed two months post-procedure. All the patients were followed up by telephone or outpatient service on the 1st and 3rd day after the procedure, and adverse events were recorded. All individuals underwent general anesthesia and were fitted with a laryngeal mask.

Detailed Description

See details in"Brief summary"

Recruitment & Eligibility

Status
RECRUITING
Sex
All
Target Recruitment
150
Inclusion Criteria

Not provided

Exclusion Criteria

Not provided

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
The diagnostic yield of OCT or R-EBUS-guided TBB in PPLsbaseline

Ability to locate PPLs

Secondary Outcome Measures
NameTimeMethod
The demographics of all patientsbaseline and 2 months

age(year), gender(male, female), and smoking history(yes or no),the location and size of the lesions, airway grades (ranging from 0 to 24) that the PPLs located, location time(seconds) of OCT and the number of specimens(number=1,2,3...),surgical biopsies, CT-guided percutaneous transthoracic needle biopsies, or other diagnostic avenues, including chest CT performed two months post-procedure

The pathological diagnostic value of OCT and R-EBUSbaseline

The ability to distinguish between benign and malignant lesions and pathological classification of malignant lesions by using OCT and R-EBUS

Trial Locations

Locations (1)

Sichuan Provincial People's Hospital

🇨🇳

Chengdu, Sichuan, China

© Copyright 2025. All Rights Reserved by MedPath