MedPath

Radiation Exposure of ERCP Personnel at Different Standing Locations and Different Patient Positions.

Not Applicable
Completed
Conditions
Occupational Radiation Exposure
Interventions
Radiation: Automatic beam adjustment function
Registration Number
NCT02791659
Lead Sponsor
Chulalongkorn University
Brief Summary

X-ray beam produced during endoscopic retrograde cholangiopancreatography (ERCP) affect not only the patient, but the personnel of ERCP team may have the effect from the scattered ray. According to the automatic beam adjustment function, the thicker object (eg. lying left lateral) might produce higher scatter ray than thinner object (eg. lying prone). The investigators evaluate the radiation exposure among ERCP personnel compare between patient's 2 different positions.

Detailed Description

Personal solid-state dosimeters were used to measure the radiation dose on personnel during ERCP procedure. The real-time effective doses were displayed at a monitoring screen. A dosimeter was attached outside thyroid collar of each ERCP team member included of 1st endoscopist, 2nd endoscopist, and nurse anesthetist.

Patients' age, gender, BMI, body thickness, and indications for ERCP were recorded. The patients were randomized into 2 groups by block-of-four. The patients' position was assigned to prone or left lateral decubitus. Each ERCP personnel wore a lead apron and the dosimeter was attached outside the thyroid collar. The ERCP procedure was performed according to the indication in a standard technique. After ERCP procedure, the total fluoroscopic time (minute), fluoroscopy tube voltage (kV), fluoroscopy tube current (mA), patient entrance skin dose (mGy) and personnel effective dose (Sv) from each dosimeter were recorded.

Continuous variables were compared by Student's t-test or Man Whitney U-test, where appropriate. Categorical variables were compared by Chi-square or the Fisher exact test. Statistical analysis was calculated by using SPSS statistical software (version17 for Window, Chicago, USA) and two sided p-value \< 0.05 was considered to be statistical significant.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
55
Inclusion Criteria
  • Indicated for ERCP
Exclusion Criteria
  • pregnancy
  • American Society of Anesthesiologists (ASA) physical status class III - IV
  • unstable vital signs
  • patients' position needed to be changed during the procedure
  • patients who need fixed position for ERCP (such as biliary hilar lesion)
  • enteroscope-assisted ERCP
  • the consent form can not be obtained

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Left lateral decubitusAutomatic beam adjustment functionIn this group, the position will be assigned to Left lateral decubitus during ERCP. The radiation from fluoroscopy will be adjusted by automatic beam adjustment function to obtain the image quality.
ProneAutomatic beam adjustment functionIn this group, the position will be assigned to Prone during ERCP. The radiation from fluoroscopy will be adjusted by automatic beam adjustment function to obtain the image quality.
Primary Outcome Measures
NameTimeMethod
Effective Radiation DoseImmediate after procedure

The effective radiation which represents equivalent dose to eye lens of each personnel were compared between 2 groups.

Secondary Outcome Measures
NameTimeMethod
© Copyright 2025. All Rights Reserved by MedPath