Correlation Between End-tidal CO2 and Degree of Compression of Heart Cavities Measured by Transthoracic Ultrasound During Cardiopulmonary Resuscitation for Out-of-hospital Cardiac Arrest
试验速览
- 阶段
- 不适用
- 发起方
- 入组人数
- 20
- 试验地点
- 1
- 主要终点
- Correlation of EtCO2 level and compression index of left ventricle, right ventricle and inferior caval vein
研究概览
简要总结
Individual optimization of cardiopulmonary resuscitation (CPR) in real time may increase the success rate of the procedure. End-tidal CO2 (EtCO2) levels reflect cardiac output induced by CPR. Other potential marker of haemodynamic efficacy of CPR is direct measurement of the extent of induced compression of left ventricle (LV), right ventricle (RV) and inferior caval vein (IVC) by ultrasound. We plane to evaluate whether these ultrasound parameters correlate with EtCO2 levels during CPR for out-of-hospital cardiac arrest (OHCA) of non-traumatic origin.
详细描述
Pre-hospital observational study will be realized in the setting of physician-based Emergency Medical System in the Czech republic. 20 patients resuscitated for OHCA of nontraumatic origin are planned to be included to the study. Transthoracic echocardiography will be performed from subcostal view during ongoing chest compressions in all of them and in the time of this investigation EtCO2 level will be recorded. This will be repeated three times during CPR in each patient if possible. Later on, maximal and minimal diameter of LV, RV and IVC will be obtained from the recorded loops and compression index (%) of LV (LVCI), RV (RVCI) and IVC (IVCCI) will be calculated as (maximal-minimal/maximal cavital diameter)x100. Correlations between EtCO2 and LVCI, RVCI and IVCI and CImax will be expressed as Spearman's correlation coefficient.
The results of the study will answer the question whether echocardiographic evaluation of compression of heart cavities during CPR reflect haemodynamic efficacy of CPR. If so, this study will be followed by an interventional clinical trial evaluating the effect of compression depth changes as a response to measured compression of the heart.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Adult patient resuscitated for out-of-hospital cardiac arrest of non-traumatic origin.
排除标准
- •Technical unavailability of intra-arrest ultrasonography and capnography.
结局指标
主要结局
Correlation of EtCO2 level and compression index of left ventricle, right ventricle and inferior caval vein
时间窗: Participant will be repeatedly evaluated during cardiopulmonary resuscitation. Therefore, anticipated time frame the time interval will fluctuate from 5 minutes to 120 minutes
Compression index of left ventricle, right ventricle and inferior caval vein measured by intra-arrest echocardiography and EtCO2 measured by side stream approach during cardiopulmonary resuscitation.
次要结局
未报告次要终点
研究者
Roman Skulec
Roman Skulec, MD, PhD
Emergency Medical Service of the Central Bohemian Region, Czech Republic
