MedPath

Carbon Dioxide Rebreathing During Exercise Assisted by Non-invasive Ventilation

Not Applicable
Completed
Conditions
Pulmonary Disease, Chronic Obstructive
Registration Number
NCT02655484
Lead Sponsor
Guangzhou Institute of Respiratory Disease
Brief Summary

The purpose of this study was to evaluate whether CO2 rebreathing occurs in healthy subjects or patients with COPD ventilated during exercise assisted by the single-limb circuit with a plateau exhalation valve at a given inspiratory positive airway pressure and a minimal level of expiratory positive airway pressure (EPAP) and whether there is a potential threshold for predicting CO2 rebreathing.

Detailed Description

Non-invasive ventilation circuit consists of single-limb tubing for inspiration and expiration, including a plateau exhalation valve. As exhaled gases was vented out the plateau exhalation valve at a constant rate, during exercise, with the increase of exhalation flow, single-limb circuit with a plateau exhalation valve might cause carbon dioxide(CO2) rebreathing. Therefore, our aim in the present study was to evaluate whether CO2 rebreathing occurs in COPD patients ventilated during exercise assisted by the single-limb circuit with a plateau exhalation valve and estimate a potential threshold for predicting CO2 rebreathing.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
18
Inclusion Criteria
  • presented clinically stable (no exacerbation in the 4 weeks prior to study participation or with no change in medications);
  • physician diagnosed COPD, forced expiratory volume in 1s (FEV1) < 50% predicted;
  • dyspnea as a main symptom that limited daily activities.
Exclusion Criteria
  • subjects with obvious pulmonary bullae demonstrated by chest CT scan or X-ray;
  • examination or facial trauma/malformation, recent facial, upper airway or upper gastrointestinal tract surgery, that would preclude receiving NIV therapy;
  • a history of coronary artery disease or cardiac arrhythmias or potential electrocardiographic alterations;
  • a history of uncontrolled hypertension, or other respiratory diseases;
  • oxygen saturation(SpO2) < 88% at rest with a fraction of inspired oxygen (FiO2) ≥ 0.5;
  • patients with musculoskeletal or neurological disorders;
  • or failure to comply with the research protocol.

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Primary Outcome Measures
NameTimeMethod
mean exhalation valve flowMeasurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process.
Secondary Outcome Measures
NameTimeMethod
mean inspiratory fraction of CO2 for each tidal volumeMeasurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process.
fraction of end-tidal carbon dioxide partial pressureMeasurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process.
inspiratory timeMeasurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process.
expiratory timeMeasurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process.
respiratory rateMeasurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process.
mean exhalation flowMeasurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process.
inspiratory tidal volumeMeasurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process.
expiratory tidal volumeMeasurements were collected continuously throughout a symptom-limited cycle exercise test (test lasts for about 8-12 min) while subjects breathed through the full face mask. Analyses were made breath by breath during the whole test process.

Trial Locations

Locations (1)

State Key Laboratory of Respiratory Disease, First Affiliated Hospital of Guangzhou Medical University

🇨🇳

Guangzhou, Guangdong, China

State Key Laboratory of Respiratory Disease, First Affiliated Hospital of Guangzhou Medical University
🇨🇳Guangzhou, Guangdong, China