Effect of dose, interval and rate of bolus dialysate infusion for hypotension in intermittent infusion hemodiafiltratio
Not Applicable
- Conditions
- Chronic kidney disease with hemodialysis
- Registration Number
- JPRN-UMIN000028145
- Lead Sponsor
- Tohto Sangenjaya Clinic
- Brief Summary
Among patients with a body weight of 52 kg or more, the blood pressure was more stable when a bolus fluid volume of 200 mL was used, compared with a volume of 100 mL. Among patients with a body weight of less than 52 kg, however, the significance of the difference in bolus fluid volumes disappeared.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- Complete: follow-up complete
- Sex
- All
- Target Recruitment
- 77
Inclusion Criteria
Not provided
Exclusion Criteria
They had active inflammatory disease or malignancy
Study & Design
- Study Type
- Interventional
- Study Design
- Not specified
- Primary Outcome Measures
Name Time Method Change of blood pressure and heart rate
- Secondary Outcome Measures
Name Time Method Intervention frequency for hypotension KT/V