Evaluation of the Relationship Between Preoperative Cardiopulmonary Performance Indicators (Hand Grip Strength and 6-Minute Walk Test) and Preoxygenation and Oxygen Reserve
试验速览
- 阶段
- 不适用
- 状态
- 尚未招募
- 入组人数
- 120
- 主要终点
- Preoxygenation Efficiency (EtO_2 Time)
研究概览
简要总结
The goal of this observational study is to evaluate the relationship between preoperative cardiopulmonary performance indicators and preoxygenation efficiency along with oxygen reserve depletion in patients scheduled for elective surgery under general anesthesia. The main questions it aims to answer are:
What is the relationship between Hand Grip Strength (HGS) and the time taken for end-tidal oxygen (EtO_2) to reach 90% during preoxygenation? What is the relationship between the 6-Minute Walk Test (6MWT) distance and the Oxygen Reserve Index (ORI) depletion time during the apnea period?
Participants will be asked to perform the following tasks during their preoperative and intraoperative care:
Complete a 6-Minute Walk Test (6MWT) to determine preoperative functional capacity.
Perform a Hand Grip Strength (HGS) test using a calibrated hand dynamometer to measure muscle strength.
Undergo standardized preoxygenation with 100% oxygen via a tight-fitting face mask in the operating room while end-tidal oxygen (EtO_2) and Oxygen Reserve Index (ORI) levels are continuously monitored.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Prospective
入排标准
- 年龄范围
- 18 Years 至 —(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •Patients aged >18 years ASA physical status I-III Scheduled for elective surgery under general anesthesia Voluntary written informed consent to participate in the study
排除标准
- •Severe COPD (Chronic Obstructive Pulmonary Disease) or restrictive lung disease NYHA Class III-IV Heart Failure Neuromuscular diseases Upper extremity pathologies affecting hand function (preventing HGS measurement) Orthopedic or neurological conditions preventing the 6-minute walk test (6MWT) Emergency surgeries
结局指标
主要结局
Preoxygenation Efficiency (EtO_2 Time)
时间窗: From the initiation of preoxygenation (0 seconds) until the EtO_2 values reach 90% (typically within 3 to 5 minutes before anesthesia induction)
The time taken for end-tidal oxygen (EtO\_2) to reach 90% during preoxygenation.
Oxygen Reserve Depletion Time (ORI Time)
时间窗: From the cessation of preoxygenation/initiation of apnea until the ORI drops below 0.55
The time duration for the Oxygen Reserve Index (ORI) value to drop below 0.55.
次要结局
- Preoperative Functional Capacity (6MWT)(Preoperative period)
- Preoperative Muscle Strength (HGS)(Preoperative period)
研究者
Betül Güven
Assos prof
Ankara City Hospital Bilkent
