Skip to main content
Clinical Trials/NCT02407418
NCT02407418CompletedNot Applicable

The Effects of Lumbosacral Manipulation on Isokinetic Strength of the Knee Extensors and Flexors

Grant Sanders0 sites21 target enrollmentStarted: April 1, 2012Last updated:
Conditions
Interventions

Trial Snapshot

Phase
Not Applicable
Status
Completed
Sponsor
Enrollment
21
Primary Endpoint
Changes in isometric and isokinetic peak torques compared to baseline

Study Overview

Brief Summary

The purpose of this study was to investigate the effects of chiropractic low back adjustments on thigh muscle strength. Force production was measured during different types of muscle contractions with a device called an isokinetic dynamometer. The study included 21 college-aged subjects who did not have any pain and had never received chiropractic treatment with spinal manipulation. During two separate sessions, subjects' thigh muscle forces were recorded while performing maximal muscle contractions on the isokinetic dynamometer. Baseline measurements of muscle force were acquired before either treatment form of spinal manipulation or a sham spinal manipulation, followed by identical muscle force measurements within five and twenty minutes post-treatment.

Detailed Description

Spinal manipulation is a therapeutic procedure employed by various healthcare practitioners for alleviating acute and chronic musculoskeletal complaints. This form of treatment is also delivered to enhance the performance and augment the rehabilitation of athletes. However, despite research findings alleging the strength-modulating effects of spinal manipulation alongside numerous professional athletes' positive anecdotal claims concerning its results, the physiological processes to explain its effects remain largely unexplained. Therefore, the purpose of this work was to investigate the effects of spinal manipulation in a college-aged sample population.

This study examined the effect of spinal manipulation delivered to the lumbosacral region on concentric force production of the knee extensors and flexors. A randomized, controlled, single-blind repeated measures design was utilized with 21 subjects. Isometric and isokinetic peak torques (Nm) were recorded during two separate session while subjects performed maximal voluntary contractions post-treatment of either spinal manipulation or a sham manipulation.

Study Design

Study Type
Interventional
Allocation
Randomized
Intervention Model
Crossover
Primary Purpose
Basic Science
Masking
Single (Participant)

Eligibility Criteria

Ages
20 Years to 35 Years (Adult)
Sex
All
Accepts Healthy Volunteers
Yes

Inclusion Criteria

  • •Between the ages of 20 to 35 years
  • •Asymptomatic with regard to low back, pelvic or lower extremity pain

Exclusion Criteria

  • •Previously received spinal manipulation from a chiropractor or other health care provider
  • •Contraindications to lumbar spine manipulation (such as fractures, lumbar disc herniation, abdominal aortic aneurysm or cauda equina syndrome)

Arms & Interventions

Spinal Manipulation

Active Comparator

In a repeated measures, crossover design, all subjects received spinal manipulation during the second or third session. The selection of spinal manipulation or sham was randomized.

Intervention: Spinal Manipulation (Other)

Sham Manipulation

Sham Comparator

In a repeated measures, crossover design, all subjects received the sham manipulation during the second or third session. The selection of spinal manipulation or sham was randomized.

Intervention: Sham Manipulation (Other)

Outcomes

Primary Outcomes

Changes in isometric and isokinetic peak torques compared to baseline

Time Frame: Baseline peak torque measurements were acquired before either treatment form of lumbosacral manipulation or sham manipulation, followed by identical peak torque measurements recorded within 5 minutes and at 20 minutes post-treatment

Peak torque measurements were recorded in newton meters (Nm) while subjects performed maximal voluntary contractions of concentric knee extension and flexion during a randomized protocol of isometric and isokinetic contractions, all of which measured with an isokinetic dynamometer

Secondary Outcomes

No secondary outcomes reported

Investigators

Sponsor
Grant Sanders
Sponsor Class
Other
Responsible Party
Sponsor Investigator
Principal Investigator

Grant Sanders

Sponsor/Investigator

University of Kentucky

Similar Trials