跳至主要内容
临床试验/NCT01354769
NCT01354769
已完成
不适用

Capnography Library - Data Collection in the Critical Care Environment Stage 2

Shaare Zedek Medical Center1 个研究点 分布在 1 个国家目标入组 75 人2011年6月

概览

阶段
不适用
干预措施
未指定
疾病 / 适应症
Respiratory Insufficiency
发起方
Shaare Zedek Medical Center
入组人数
75
试验地点
1
状态
已完成
最后更新
10年前

概览

简要总结

Capgnography is the monitoring of the concentration or partial pressure of carbon dioxide in the expired respiratory gases; as such, it is a non-invasive monitoring technique which allows fast and reliable insight into ventilation, circulation and metabolism. Capnography has proven to be more effective than clinical judgement alone in the early detection of adverse respiratory events. The shape of a capnogram is identical in all humans with healthy lungs; any deviations in shape must be investigated to determine a physiological or a pathological cause of the abnormality.

Data from a previous pilot study yielded two major findings:

  1. Prediction of requirement for intubation, by the creation of an "Integrated Pulmonary Index" (IPI) based on non-invasive physiological parameters
  2. Breathing patterns during weaning in order to identify specific patterns used to predict extubation success/failure

The intent of the current study is to gather sufficient data to either prove or disprove the findings of the previous study

详细描述

The patient's monitoring period will be as follows: Non-intubated patients - Initiation: As soon as possible after admission and/or extubation and no later than 24 hours after either. Termination- either 2 hours after intubation or after 8 hours of monitoring overall. Intubated patients - Initiation: No later than 24 hours after a decision to begin weaning has been made . Termination: Upon ICU (Intensive Care Unit) discharge or for the duration of 10 days at most. Data will be collected using three tools: 1. CapnoStream raw data (CO2 (Carbon dioxide) waveform, EtCO2 (End-tidal Carbon dioxide), respiratory rate, SpO2 (Saturation of peripheral Oxygen), pulse rate, IPI, alarms, events and any other messages generated by the monitor) will be transferred from the monitor to a laptop via a dedicated recording program. 2. Ventilator data (settings and resultant patient parameters) will be transferred from the monitor to a laptop via a dedicated recording program. 3. Patient monitoring parameters (heart rate, blood pressure, CVP (Central Venous Pressure), temperature, spirometry values etc) shall be recorded from the multi parameter monitors already in use in the ICU and transferred online to a laptop using dedicated recording software. All recorded parameters will be synchronized. Data will be recorded from at least two of the tools, the Capnostream and the ventilator.

注册库
clinicaltrials.gov
开始日期
2011年6月
结束日期
2015年1月
最后更新
10年前
研究类型
Observational
性别
All

研究者

责任方
Sponsor

入排标准

入选标准

  • Over the age of 18
  • Suffering from severe illness requiring admission to the ICU
  • Expected to be hospitalized in the ICU for a minimum of 8 hours

排除标准

  • Under the age of 18
  • The patient's refusal to participate in the study
  • Any change in the patient's condition that may interfere with data collection

结局指标

主要结局

未指定

研究点 (1)

Loading locations...