MedPath

Functional and Physiological Changes Induced by Pinhole Glasses in Presbyopia

Not Applicable
Conditions
Pinhole
Interventions
Device: Trayner Pinhole Glasses (Trayner Glasses, Ivybridge Devon, U.K.)
Registration Number
NCT02722291
Lead Sponsor
Chung-Ang University Hosptial, Chung-Ang University College of Medicine
Brief Summary

This study is aimed at presbyopic patients that do not require magnifying glass at close rage. The purpose of this study is to investigate the functional and physiological changes in eye induced by pinhole glass.

Detailed Description

Not available

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
40
Inclusion Criteria
  1. age over 45 years
  2. spherical equivalents(SE) within ± 3.0 diopters(D)
  3. normal ocular alignment
Exclusion Criteria
  1. disturbance of accommodation due to any reasons such as an Adie's pupil, Parkinson's disease, a history of previous ocular surgery or trauma, and a history of systemic or topical medication that might affect accommodation
  2. corneal pathologic features
  3. glaucoma
  4. cataracts of grade II or greater by the Lens Opacities Classification System III (LOCS III)
  5. vitreous and retinal abnormalities that might limit the accuracy of testing

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
presbyopiaTrayner Pinhole Glasses (Trayner Glasses, Ivybridge Devon, U.K.)All participants perform all exams under 3 conditions, that is baseline, with out pinhole glasses, and with multiple pinhole glasses
Primary Outcome Measures
NameTimeMethod
Pupil size with the one eye pinhole glasses (mm)Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study

Pupil size with the one eye pinhole glasses was measured using a WASCA Analyzer (Carl Zeiss Meditec, Oberkochen, Germany).

StereopsisSubjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study

Stereopsis was checked with the Randot Stereotest (Stereo Optical Co., Chicago, IL, USA).

Reading speed (letters per second)Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study

Reading speed was evaluated using the famous Korean traditional fairy tale book. This Korean book was printed black-and-white with 10-font size.

Distant visual acuity (logMAR)Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study

Distant visual acuity were measured using Snellen chart (Precision Vision, La Salle, IL, USA) at 4 m.

The fusional convergenceSubjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study

With the subject watching the 20/30 sized fixation target at 40 cm, we take the base-out bar prism on the subject's right eye. While gradually increasing the extent of the prism, the first point that the subject noticed diplopia was defined as the break point.

BUTSubjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study

fluorescein is instilled into the subject's tear film and the subject is asked not to blink while the tear film is observed under a broad beam of cobalt blue illumination

Near point of accommodation (NPA)Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study

Near point of accommodation (NPA) was measured using Donder's push-up method.

Photopic pupil size (baseline, mm)Subjects performed this examination while wearing multiple pinhole and without wearing pinhole with one week apart in random order after baseline study

Pupil size under photopic conditions (85 cd/m2) was measured using a WASCA Analyzer (Carl Zeiss Meditec, Oberkochen, Germany).

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Chung-Ang University Hospital

🇰🇷

Seoul, Korea, Republic of