Prediction of Primary Dental Implant Stability Preoperatively Using CBCT of the Planned Implant Site.
- Conditions
- Prediction of Primary Implant Stability From Bone Quality Obtained Prior to Implant Placement Using CBCT
- Registration Number
- NCT06654518
- Lead Sponsor
- Soaad Tolba Mohammed Tolba Badawi
- Brief Summary
This study aimed to assess whether preoperative characteristics of the implant site, such as bone density and alveolar ridge width, assessed using cone beam computed tomography (CBCT), are significantly associated with primary stability, as assessed by resonance frequency analysis (RFA) and final insertion torque value (ITV), and thereby investigate if it is feasible to predict primary stability preoperatively using this form of radiologic examination of the planned implant site. All patients underwent preoperative CBCT. The bone density and alveolar ridge width were assessed. The primary implant stability quotient (ISQ) values were assessed by a wireless magnetic-based Osstell ISQ RF Analyzer.
- Detailed Description
The quality and quantity of bone available for placing dental implants are key factors in the success of these implants. Implants placed in bone with insufficient quantity or poor quality have a higher risk of failure. As a result, evaluating the bone structure prior to implant placement surgery is essential for proper planning of the treatment.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 72
- Patients must be free from any systemic conditions that would contraindicate dental implant surgery.
- Good oral hygiene.
- Age above 18 years.
- The planned implant site must have sufficient alveolar bone volume.
- Patients who have undergone radiation therapy to the head and neck region within the last 12 months.
- Uncontrolled diabetes.
- Patients who underwent dental extractions or bone augmentation at the planned implant site during the last six months in order to guarantee uniform bone maturation.
- Severe clenching or bruxism is present.
- Acute infection at the planned implant site.
- Implant sites requiring a procedure for bone gain.
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Primary Outcome Measures
Name Time Method Primary Implant Stability Using Resonance Frequency Analysis (RFA)and final insertion torque value (ITV) Measured immediately after implant placement The primary outcome measure was the primary stability of the dental implants as determined by resonance frequency analysis (RFA) and final insertion torque value (ITV). The Implant Stability Quotient (ISQ) was measured immediately after the implant placement. ITV and ISQ values were corelated with the preoperative CBCT measurements of bone density and alveolar ridge width to evaluate the prognostic accuracy of CBCT in predicting primary implant stability.
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (1)
Faculty of Dentistry, Mansoura University
🇪🇬Mansoura., Dakahlia, Egypt