Myotonometric Measurement of Myofascial Trigger Points: Reliability, Validity and Sensitivity

Completed
Conditions
Muscle Tone Abnormalities
Registration Number
NCT02919150
Lead Sponsor
University of Castilla-La Mancha
Brief Summary

The aims of this study are:

* To examine the inter-rater reliability to assess myofascial trigger points using a myotonometer

* To determinate the strength of the correlation between myotonometric parameters and isokinetic parameters

* To evaluate the sensitivity of myotonometric measurements to detect the location of myofascial trigger points

Detailed Description

Previous researches have used complicated and expensive methods to measure mechanical properties of muscle tone like isokinetic dynamometer.

The purpose of this investigation is to establish the reliability, validity and sensitivity of a myotonometer to assess myofascial trigger points. The results of this study will verify the inter-reliability of a myotonometer device in order to evaluate muscle tone, examine correlations and associations between myotonometric measurements and isokinetic measurements and provide a measurable understanding of the location of myofascial trigger points.

Assessment:

Myoton device is a simple and portable tool to obtain quantitative and objective assessments of mechanical properties of muscle tone.

Isokinetic dynamometric technique is considered a valid biomechanics method to measure muscle tone in non-injured subjects but isokinetic machine is a heavy and expensive equipment.

Outcome measures:

Myotonometric measures will include muscle frequency, decrement (elasticity) and stiffness.

Isokinetic measures will include passive resistive torque to ankle dorsiflexion and dorsiflexion passive range of motion (PROM)

All outcome measures will be evaluated once.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
50
Inclusion Criteria
  • Age range 18-55 years.
  • Healthy volunteers.
  • Presence of a latent medial MTrP of the soleus muscle.
  • Being able to provide written informed consent.
  • Being able to follow instructions and realize clinical tests.
Exclusion Criteria
  • Any history of ipsilateral lower limb severe injury or intervention (e.g. fracture, surgical intervention).
  • Pain or musculoskeletal injury, ligament injury, tendonitis or plantar fasciitis in the ipsilateral leg for six months previous to the evaluation.
  • Peripheral or central nervous system neurological disease.
  • Altered sensitivity in the studied area.
  • Treatment of a myofascial trigger point in the sural triceps in the six months previous to the evaluation.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Inter-rater reliability of myotonometric measurementDay 1

In order to study the interrater reliability of the myoton, two different evaluators assess the muscle tone within two marked points using the myotonometer

Correlation between myotonometric measurement and isokinetic measurementDay 1

Relationships among myotonometric parameters and isokinetic parameters

Sensitivity of distinguishing the localisation of myofascial trigger points within the taut bandDay 1

Ability to identify and differentiate myofascial trigger points and other points within the taut band using the myotonometer