The Feasibility of Florbetapir Quantitation in Europe

Phase 4
Completed
Conditions
Alzheimer's Disease
Interventions
Registration Number
NCT02107599
Lead Sponsor
Avid Radiopharmaceuticals
Brief Summary

This study will evaluate whether the addition of quantitation as an adjunct to visual interpretations significantly improves the accuracy of Amyvid scan interpretation.

Detailed Description

Not available

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
96
Inclusion Criteria
  • Readers have undergone Amyvid reader training
  • Readers have not more than minimal experience with quantitation of amyloid PET scans
Exclusion Criteria
  • Readers have previously been trained to quantitate amyloid PET scans

Study & Design

Study Type
INTERVENTIONAL
Study Design
SINGLE_GROUP
Arm && Interventions
GroupInterventionDescription
Physician ReadersFlorbetapir (18F)Physician readers will interpret Amyvid scans using qualitative analysis followed by the use of quantitation. No subjects will be exposed to Florbetapir(18F) as part of this study.
Primary Outcome Measures
NameTimeMethod
Change in Reader Accuracy After Application of Quantitation SoftwareScan acquired 50-60 minutes post injection

Evaluate whether the use of quantitation software improves florbetapir (18F) scan interpretation by using the net reclassification index (NRI). The NRI is a prospective measure that quantifies the correctness of upward and downward reclassification or movement of predicted probabilities as a result of adding a new marker. NRI Values \>0 indicate an improvement in scan interpretation accuracy and values \<0 indicate a decline in scan interpretation accuracy after application of quantitation software.

NRI = \[P(up,event)-P(down,event)\]-\[P(up,nonevent)-P(down,nonevent)\] Where P(up,event) = # events up/# events P(down,event) = # events down/# events P(up,nonevent) = # nonevents up/# nonevents P(down,nonevent) = # nonevents down/# nonevents and events: true positive case nonevents: true negative case up: scan change from negative to positive down: scan change from positive to negative

Only the 46 scans with autopsy from A16 are used for this outcome measure.

Secondary Outcome Measures
NameTimeMethod
Change in Scan Interpretation Reliability After Application of Quantitation SoftwareScan acquired 50-60 minutes post injection

Evaluate whether the use of quantitation software improves florbetapir (18F) scan interpretation by using the net reclassification index (NRI). The NRI is a prospective measure that quantifies the correctness of upward and downward reclassification or movement of predicted probabilities as a result of adding a new marker. NRI Values \>0 indicate an improvement in scan interpretation accuracy and values \<0 indicate a decline in scan interpretation accuracy after application of quantitation software.

NRI = \[P(up,event)-P(down,event)\]-\[P(up,nonevent)-P(down,nonevent)\] Where P(up,event) = # events up/# events P(down,event) = # events down/# events P(up,nonevent) = # nonevents up/# nonevents P(down,nonevent) = # nonevents down/# nonevents and events: true positive case nonevents: true negative case up: scan change from negative to positive down: scan change from positive to negative

Only the 46 scans with autopsy from A16 are used for this outcome measure.

Trial Locations

Locations (1)

Research Site

🇳🇱

Leiden, Netherlands