The Feasibility of Florbetapir Quantitation in Europe
- Registration Number
- NCT02107599
- Lead Sponsor
- Avid Radiopharmaceuticals
- Brief Summary
This study will evaluate whether the addition of quantitation as an adjunct to visual interpretations significantly improves the accuracy of Amyvid scan interpretation.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- All
- Target Recruitment
- 96
- Readers have undergone Amyvid reader training
- Readers have not more than minimal experience with quantitation of amyloid PET scans
- Readers have previously been trained to quantitate amyloid PET scans
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description Physician Readers Florbetapir (18F) Physician readers will interpret Amyvid scans using qualitative analysis followed by the use of quantitation. No subjects will be exposed to Florbetapir(18F) as part of this study.
- Primary Outcome Measures
Name Time Method Change in Reader Accuracy After Application of Quantitation Software Scan acquired 50-60 minutes post injection Evaluate whether the use of quantitation software improves florbetapir (18F) scan interpretation by using the net reclassification index (NRI). The NRI is a prospective measure that quantifies the correctness of upward and downward reclassification or movement of predicted probabilities as a result of adding a new marker. NRI Values \>0 indicate an improvement in scan interpretation accuracy and values \<0 indicate a decline in scan interpretation accuracy after application of quantitation software.
NRI = \[P(up,event)-P(down,event)\]-\[P(up,nonevent)-P(down,nonevent)\] Where P(up,event) = # events up/# events P(down,event) = # events down/# events P(up,nonevent) = # nonevents up/# nonevents P(down,nonevent) = # nonevents down/# nonevents and events: true positive case nonevents: true negative case up: scan change from negative to positive down: scan change from positive to negative
Only the 46 scans with autopsy from A16 are used for this outcome measure.
- Secondary Outcome Measures
Name Time Method Change in Scan Interpretation Reliability After Application of Quantitation Software Scan acquired 50-60 minutes post injection Evaluate whether the use of quantitation software improves florbetapir (18F) scan interpretation by using the net reclassification index (NRI). The NRI is a prospective measure that quantifies the correctness of upward and downward reclassification or movement of predicted probabilities as a result of adding a new marker. NRI Values \>0 indicate an improvement in scan interpretation accuracy and values \<0 indicate a decline in scan interpretation accuracy after application of quantitation software.
NRI = \[P(up,event)-P(down,event)\]-\[P(up,nonevent)-P(down,nonevent)\] Where P(up,event) = # events up/# events P(down,event) = # events down/# events P(up,nonevent) = # nonevents up/# nonevents P(down,nonevent) = # nonevents down/# nonevents and events: true positive case nonevents: true negative case up: scan change from negative to positive down: scan change from positive to negative
Only the 46 scans with autopsy from A16 are used for this outcome measure.