The Characteristics of Backscattering With Depth in the Progression of Keratoconus

Completed
Conditions
Elasticum, Incomplete Pseudoxanthoma
Registration Number
NCT06050629
Lead Sponsor
Tianjin Eye Hospital
Brief Summary

To investigate the variation in backscattering with depth between forme fruste keratoconus (FFKC), keratoconus, and normal eyes; to determine the backscattering changes in the characteristics of keratoconus progression; and to explore the diagnostic value of backscattering in FFKC.

Detailed Description

To investigate the variation in backscattering with depth between forme fruste keratoconus (FFKC), keratoconus, and normal eyes; to determine the backscattering changes in the characteristics of keratoconus progression; and to explore the diagnostic value of backscattering in FFKC. A Scheimpflug corneal tomography image and caliper tool were used to obtain backscatter at every 2% depth at the thinnest point of the cornea, with the measured values expressed in grayscale units (GSU).

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
223
Inclusion Criteria
  1. BCVA <20/20 and a history of myopia or astigmatism;
  2. presence of any of the following positive signs on slit lamp examination: corneal stromal thinning, cone-shaped anterior protrusions, Fleischer's ring, Vogt's striae, epithelial or subepithelial scarring;
  3. abnormal corneal topography (maximum keratometry (K) value of >47.2 diopters (D), bow-tie pattern with skewed radial axes, or inferior-superior asymmetry(3-mm I-S keratometric difference >1.4 D).
Exclusion Criteria
  1. Patients with severe corneal scarring that affected light scattering and density maps showing "black holes" 2.Participatients with other corneal diseases 3. Eyes that have undergone surgery or trauma 4. Eyes with corneal dystrophy

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
backscatteringthrough study completion, an average of 1 year

Standard measurements were performed using a Pentacam (Pentacam HR; Oculus, Wetzlar, Germany);The average brightness of a predetermined area of the cornea was calculated, shown as densitometry, and recorded in GSU ranging from 0 to 100 (0, cornea is transparent without opacity; 100, cornea is completely opaque).

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

Tianjin Eye Hospital

🇨🇳

Tianjin, Tianjin, China