Accuracy of Pulse Oximeters With Profound Hypoxia
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 12
- 试验地点
- 1
- 主要终点
- To obtain a reading from the Respiree device that corresponds to the associated blood sample or a reference oximeter.
研究概览
简要总结
The aim of this project is to test the accuracy of pulse oximeters during mild, moderate and severe hypoxia. This is done by comparing the reading of the pulse oximeter during brief, steady state hypoxia with a gold-standard measurement of blood oxyhemoglobin saturation (arterial blood sample processed in a laboratory hemoximeter). The data obtained is submitted by pulse oximeter manufacturers to the FDA for device approval.
详细描述
The study will include at least 10 subjects (up to 14 if needed to reach the 200 necessary data points to meet the ISO 80601-2-61:2017).
Per FDA guidance, at least 2, or 15% of the subjects will have dark skin.
研究设计
- 研究类型
- Observational
- 观察模型
- Cohort
- 时间视角
- Retrospective
入排标准
- 年龄范围
- 18 Years 至 49 Years(Adult)
- 性别
- All
- 接受健康志愿者
- 是
入选标准
- •The subject is male or female, aged ≥18 and <
- •The subject is in good general health with no evidence of any medical problems.
- •The subject is fluent in both written and spoken English.
- •The subject has provided informed consent and is willing to comply with the study procedures.
排除标准
- •The subject is obese (BMI>30).
- •The subject has a known history of heart disease, lung disease, kidney or liver disease.
- •Diagnosis of asthma, sleep apnea, or use of CPAP.
- •Subject has diabetes.
- •Subject has a clotting disorder.
- •The subject a hemoglobinopathy or history of anemia, per subject report or the first blood sample, that in the opinion of the investigator, would make them unsuitable for study participation.
- •The subject has any other serious systemic illness.
- •The subject is a current smoker.
- •Any injury, deformity, or abnormality at the sensor sites that in the opinion of the investigators' would interfere with the sensors working correctly.
- •The subject has a history of fainting or vasovagal response.
- •The subject has a history of sensitivity to local anesthesia.
- •The subject has a diagnosis of Raynaud's disease.
- •The subject has unacceptable collateral circulation based on exam by the investigator (Allen's test).
- •The subject is pregnant, lactating or trying to get pregnant.
- •The subject is unable or unwilling to provide informed consent, or is unable or unwilling to comply with study procedures.
- •The subject has any other condition, which in the opinion of the investigators' would make them unsuitable for the study.
结局指标
主要结局
To obtain a reading from the Respiree device that corresponds to the associated blood sample or a reference oximeter.
时间窗: 1 hour per subject
The number of subjects and the number of comparisons (paired pulse oximeter readings and arterial saturation values) is determined by current FDA guidance requirements. This is a minimum of 200 data points and 10 subjects. In the course of this type of study, some subjects may drop out, some readings can be lost due to motion or other interference and occasionally some do not consent.