A Randomised Single Centre Study to Compare the Long-term Performance of 4 Designs of the DePuy Ultima LX Stem in Primary Total Hip Replacement
- Conditions
- Post-traumatic ArthritisCongenital Hip DysplasiaOsteoarthritisAvascular NecrosisSlipped Capital Femoral EpiphysisCollagen DisorderNonunion of Femoral FracturesTraumatic Femoral Fractures
- Interventions
- Device: Ultima LX Collarless Stem - Non-Polished/Blasted FinishedDevice: Ultima LX Collared Stem - Non-Polished/Blasted FinishedDevice: Ultima LX Collared Stem - Polished FinishedDevice: Ultima LX Collarless Stem - Polished finished
- Registration Number
- NCT00208351
- Lead Sponsor
- DePuy International
- Brief Summary
The purpose of this study is to compare the performance of 4 designs of the DePuy Ultima LX hip stem in the treatment of patients with hip joint disease requiring a total hip replacement. Patients who enter the study will be randomly allocated to one of the 4 designs of the DePuy Ultima LX hip stem and will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments.
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- TERMINATED
- Sex
- All
- Target Recruitment
- 164
Current indications for primary total hip arthroplasty utilising a cemented femoral component. These include pain, deformity and loss of function which are not responsive to medical treatment
i) Revision Total Hip Arthroplasty ii) Rheumatoid arthritis iii) Age greater than 80 years at time of surgery iv) Age less than 60 years at time of surgery v) Previous hip joint sepsis vi) Obesity vii) Patient likely to remain housebound once rehabilitation is complete
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- PARALLEL
- Arm && Interventions
Group Intervention Description 3) Ultima LX Collarless Stem - Non-Polished/Blasted Finished Ultima LX Collarless Stem - Non-Polished/Blasted Finished A collarless non-polished/blasted finished cementless femoral component for use in total hip replacement. 1) Ultima LX Collared Stem - Non-Polished/Blasted Finished Ultima LX Collared Stem - Non-Polished/Blasted Finished A collared non-polished blasted finished cementless femoral component for use in total hip replacement. 2) Ultima LX Collared Stem - Polished Finished Ultima LX Collared Stem - Polished Finished A collared polished finished cementless femoral component for use in total hip replacement. 4) Ultima LX Collarless Stem - Polished Finished Ultima LX Collarless Stem - Polished finished A collarless polished finished cementless femoral component for use in total hip replacement.
- Primary Outcome Measures
Name Time Method Stem movement measured radiographically at 2 years 2yrs post-surgery Stem movement was measured radiographically by comparing baseline stem position with the stem position 2 years after surgery. If migration was observed to be 5 or more mm, it was considered clinically significant migration.
- Secondary Outcome Measures
Name Time Method Comparisons of Visual Analog Pain (VAS), 36-Item Short Form Health Survey (SF-36), Satisfaction, Limb Length and stem movement measured radiographically at 5 years. 5yrs post-surgery The following outcome measures were used; VAS Pain score, SF36 Patient reported outcome, Satisfaction, Limb Length physical examination, and stem movement measured radiographically.
Trial Locations
- Locations (1)
Epsom General Hospital
🇬🇧Surrey, United Kingdom