Non-Invasive Measurement of SjvO2 Using Near Infrared Spectroscopy in Critically Ill Patients

Completed
Conditions
Impaired Oxygen Delivery
Critically Ill Patient
Registration Number
NCT04624009
Lead Sponsor
University Hospital, Geneva
Brief Summary

ScvO2 is an important parameter in the management of critically ill patient. The only way to measure it is to have an internal jugular or subclavian central venous catheter. With this trial, the investigators want to show a positive relationship between invasive ScvO2 measurement and noninvasive SjvO2 measurement with VO 100 medical device from Mespere LifeSciences, allowing the use of SjvO2 as a noninvasive surrogate of ScvO2 in critically ill patients.

Detailed Description

ScvO2 measures central venous oxygen saturation level from veins draining the head and upper body while SvO2 measures mixed venous oxygen saturation from the lower and upper half of the body. ScvO2 is more conveniently measured and less risky than Sv02 measurement although a central venous catheter is needed. ScvO2 gives knowledge about the balance between the delivery of oxygen and oxygen consumption in the body. Interest in ScvO2 monitoring in anesthesia and critical care has been debated. However, ScvO2 is still recommended as a major hemodynamic target of early resuscitation of critically ill patients. Even if ScvO2 measurement is far less invasive than SvO2 measurement through pulmonary artery catheter, it is accompanied with morbidity.

VO 100 medical device from Mespere LifeSciences allows a non-invasive measurement of SjvO2 using the NIRS technique. Jugular venous oxygen saturation (SjvO2) is a measurement of the amount of oxygen left in the venous system after the brain has removed the oxygen that it needs.

On the same principle that a positive relationship between ScvO2 and SvO2 has been shown, what the investigators are trying to do is to show a positive relationship between SjvO2 and ScvO2 in order to possibly use in the future SjvO2 measured by VO 100 as a noninvasive surrogate of ScvO2.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
35
Inclusion Criteria
  • all ICU adult patients routinely equipped with a central venous catheter placed in internal jugular or subclavian vein allowing ScvO2 measurement from blood sampling.

The investigators will perform this study only on patients already equipped with an internal jugular CVC. In other words, the placement of the CVC is not conditioned by the study realization.

Exclusion Criteria
  • patients with CVC placed in another site than internal jugular vein.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Comparison of venous oxygen saturation 1On admission to the intensive care unit

Comparison of ScvO2 values from CVC blood sample and SjvO2 values from the VO 100 (% oxygen saturation)

Secondary Outcome Measures
NameTimeMethod
Comparison of venous oxygen saturation 23 days after admission into the intensive care unit

Comparison of ScvO2 values from CVC blood sample and SjvO2 values from the VO 100 (% oxygen saturation)

Comparison of venous oxygen saturation 3On admission to internal medicine ward

Comparison of ScvO2 values from CVC blood sample and SjvO2 values from the VO 100 (% oxygen saturation)