Non-Invasive Measurement of SjvO2 Using Near Infrared Spectroscopy in Patients Undergoing Liver Transplantation Surgery

Completed
Conditions
Impaired Oxygen Delivery
Transplant; Failure, Liver
Registration Number
NCT04778150
Lead Sponsor
University Hospital, Geneva
Brief Summary

Mixed venous oxygen saturation (SvO2) is an important parameter in the management of patient during liver transplantation surgery especially during portal vein clamping. The only way to measure it is to use a pulmonary artery catheter. If the authors can show a positive relationship between invasive SvO2 measurement and noninvasive jugular venous oxygen saturation (SjvO2) measurement with VO 100 medical device, it will possible to use SjvO2 as a noninvasive surrogate of SvO2 in patients during liver transplantation surgery.

Detailed Description

SvO2 measures mixed venous oxygen saturation from the lower and upper half of the body. To be measured, Sv02 requires a central venous catheter. SvO2 gives knowledge about the balance between the delivery of oxygen and oxygen consumption in the body. Interest in SvO2 monitoring in anesthesia and critical care has been debated. However, SvO2 is still recommended as a major hemodynamic target of early resuscitation of critically ill patients. SvO2 measurement through pulmonary artery catheter is accompanied with morbidity due to its invasiveness. During liver transplantation surgery, measurement of SvO2 is required to adequately manage hemodynamics of the patient, especially during portal venous clamping.

VO 100 medical device from Mespere LifeSciences allows a non-invasive measurement of SjvO2 using the NIRS technique. Jugular venous oxygen saturation (SjvO2) is a measurement of the amount of oxygen left in the venous system after the brain has removed the oxygen that it needs.

On the same principle that a positive relationship between ScvO2 and SvO2 has been shown, what the investigators are trying to do is to show a positive relationship between SjvO2 and SvO2 in order to possibly use in the future SjvO2 measured by VO 100 as a noninvasive surrogate of SvO2 during liver transplantation surgery.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
20
Inclusion Criteria
  • Adult patients routinely equipped with a pulmonary artery catheter just before liver transplantation surgery allowing SvO2 measurement.
Exclusion Criteria
  • Adult patients not equipped with pulmonary artery catheter for liver transplantation surgery.

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Primary Outcome Measures
NameTimeMethod
Comparison of venous oxygen saturationContinuously during liver transplantation surgery

Comparison of SvO2 values from pulmonary artery catheter blood and SjvO2 values from the VO 100 (% oxygen saturation)

Secondary Outcome Measures
NameTimeMethod

Trial Locations

Locations (1)

University of Geneva

🇨🇭

Geneva, Switzerland