MedPath

Collared Versus Collarless Femoral Implants for Total Hip Arthroplasty

Not Applicable
Completed
Conditions
Hip Osteoarthritis
Hip Arthroplasty
Interventions
Device: Collarless Femoral Implant
Device: Collared Femoral Implant
Registration Number
NCT03558217
Lead Sponsor
Lawson Health Research Institute
Brief Summary

This is a randomized control trial that will investigate whether a collared hip replacement implant provides greater stability compared to a collarless option. Stability will be measured by implant migration with radiostereometric analysis (RSA) imaging. Secondary objectives will be to compare function, quality of life and cost between the two implant types. We will also compare between two different surgical approaches, the direct anterior and direct lateral.

Detailed Description

Total hip arthroplasty (THA) is a procedure that has been demonstrated to provide excellent patient satisfaction and improve quality of life while being cost effective. The number of THA's conducted worldwide is expected to continue to grow; in some projections to grow exponentially. However, the environment for health care continues to evolve. Patients continue to demand higher activity levels, decreased recovery times, and greater patient autonomy. Health care economics are increasingly influencing clinical decision making. Bundled health care payments and more stringent evaluations are becoming the norm. Changes in care pathways based on patient input as well as due to health care economics are our new reality.

These two pervasive forces of change have led to a variety of care challenges and thought leaders have proposed solutions to these challenges. One solution that has responded to both changing patient expectations in their THA experience as well as the economic pressures has been rapid recovery pathways. An increase in rapid recovery care pathways and the growing prevalence of outpatient surgery and surgi-centers has enabled patients to increase their autonomy as well as decrease their time away from activities that are important to them such as employment. Rapid recovery care pathways also provide substantial cost savings by diminishing or eliminating inpatient care as well as enabling improved bed management options.

To facilitate rapid recovery programs, a variety of surgical changes have been made. Improved peri-operative care, decreased muscle trauma, improved hemostasis, and multi-modal analgesia have all made positive impacts. The increasing adaptation of the Direct Anterior Approach (DAA) relative to the Direct Lateral Approach (DLA) can be seen as a response to the need for rapid recovery programs as DAA has been demonstrated to enable earlier function and is thought to result in better patient outcomes, less pain, and shorter recovery times. Orthopaedic industry partners have also supported this change in practice by providing improved instrumentation and technologies to potentiate this minimal invasive surgical approach. A key change is the increasing use of implants that facilitate muscle sparing approaches: femoral components that do no require straight femoral reamers as well as broaches and implants with design features such as an angled lateral shoulder, abbreviated stem lengths, easy to control stem tips, and stems that do not require aggressive impaction to create intimate cortical contact. The Corail both has these features that potentiate surgery as well as excellent survivorship on registry and prospective studies.

In addition to the design features that potentiate minimally invasive implantation, the Corail stem has two main designs - the collared and collarless versions. Without question, the collar provides improved axial stability, and it has also been shown to provide improved rotational stability. It is unclear if this stability enables improved early function by providing the patient the sense that their implant is more stable immediately after surgery. Clinicians also appreciate the ability to more precisely control leg length during THA by ensuring the appropriate leg length is maintained when the collar abuts the calcar. The collar is felt to enable greater initial stability to the hip and provide the surgeon with greater confidence that the patient can embark on a rapid recovery care pathway.

However, not all surgeons are as supportive of implants that have a collar nor are they supportive of implants that have a collar, and highlight a lack of literature that is able to demonstrate the benefits. A lack of literature makes it a challenge for surgeons to adopt the change in philosophy. The purpose of this study is to examine the role of surgical approach and implant design on activity and implant fixation following THA.

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
96
Inclusion Criteria
  • unilateral hip osteoarthritis
  • primary total hip arthroplasty
Exclusion Criteria
  • symptomatic osteoarthritis in the contralateral hip
  • bilateral total hip arthroplasty
  • revision arthroplasty
  • cognitive defects/neuromuscular disorders
  • inability to understand English (questionnaires are only provided in English)
  • live more than 100km from London, Ontario
  • BMI greater than 40

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Collarless Femoral ImplantCollarless Femoral ImplantParticipants will have the Corail collarless femoral implant used during their surgery.
Collared Femoral ImplantCollared Femoral ImplantParticipants will have the Corail collared femoral implant used during their surgery.
Primary Outcome Measures
NameTimeMethod
Implant Migration2 years

Movement of the implant measured by radiostereometric imaging analysis.

Secondary Outcome Measures
NameTimeMethod
Timed-Up-and-Go (TUG) Testbaseline and 2 weeks, 4 weeks, 6 weeks, 3 months, 6 months, 1 year and 2 years

Measure to assess function.

University of California, Los Angeles (UCLA) Activity Scorebaseline and 2 weeks, 4 weeks, 6 weeks, 3 months, 6 months, 1 year and 2 years

Patient-reported outcome to assess activity level.

Activity Levelbaseline and 2 weeks, 4 weeks, 6 weeks, 3 months, 6 months, 1 year and 2 years

Activity measured by number of steps taken per day with the use of a FitBit.

Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC)baseline and 3 months, 6 months, 1 year and 2 years

Used to assess impact of hip and knee osteoarthritis. Patient-reported measure to assess function, pain and stiffness. Higher scores indicate worse pain, stiffness and functional limitations. Scores are separated into 3 subscales: pain, stiffness and function; but can be combined for a total score.

Harris Hip Scorebaseline and 3 months, 6 months, 1 year and 2 years.

Used to assess impact of hip osteoarthritis. Clinician-reported outcome measure to assess function, pain and range of motion. Higher scores indicate better outcomes and hip function.

Cost Questionnaires6 weeks, 3 months, 6 months and 1 year

Patient-reported measure to assess indirect and direct costs of treatment including ER visits, clinician visits, tests and procedures, lost productivity, caregiver involvement, etc.

12-Item Short Form Health Survey (SF-12)baseline and 3 months, 6 months, 1 year and 2 years

General health questionnaire. Patient-reported measure to assess quality of life. Scores are calculated based on population averages.

EuroQol-5D (EQ-5D)baseline and 6 weeks, 3 months, 6 months and 1 year

Used to assess health-related quality of life. Patient-reported measure to assess quality of life.

Trial Locations

Locations (1)

London Health Sciences Centre

🇨🇦

London, Ontario, Canada

© Copyright 2025. All Rights Reserved by MedPath