NCT02289664
Unknown
Not Applicable
A Comparison of Coopdech, Intubrite, and CoPilot Video-laryngoscopes With Macintosh Laryngoscope for Tracheal Intubation in Pediatric Patients During Resuscitation. Randomized Crossover Manikin Trial
International Institute of Rescue Research and Education1 site in 1 country80 target enrollmentNovember 2014
ConditionsCardiac Arrest
Overview
- Phase
- Not Applicable
- Intervention
- Not specified
- Conditions
- Cardiac Arrest
- Sponsor
- International Institute of Rescue Research and Education
- Enrollment
- 80
- Locations
- 1
- Primary Endpoint
- Success of intubation
- Last Updated
- 11 years ago
Overview
Brief Summary
We hypothesized that the video-laryngoscopes are beneficial for intubation of pediatric manikins while performing CPR. In the current study, we compared effectiveness of three video-laryngoscopes and Macintosh (MAC) laryngoscopes during pediatric resuscitation with and without chest compressions using an child manikin.
Investigators
Lukasz Szarpak
Lukasz Szarpak
National Institute of Cardiology, Warsaw, Poland
Eligibility Criteria
Inclusion Criteria
- •Give voluntary consent to participate in the study
- •minimum 1 year of work experience in health care
Exclusion Criteria
- •Not meet the above criteria
- •Wrist or Low back diseases
Outcomes
Primary Outcomes
Success of intubation
Time Frame: 1 MONTH
effectiveness of first, second and third intubation attempts and overall effectiveness of intubation by participants using each device
Secondary Outcomes
- Intubation time(1 MONTH)
- POGO score(1 mONTH)
- Cormack-Lehane grading(1 MONTH)
Study Sites (1)
Loading locations...
Similar Trials
Unknown
Not Applicable
Pediatric Intubation During CPRCardiac ArrestNCT02289677International Institute of Rescue Research and Education100
Completed
Not Applicable
Comparison of Different Video Laryngoscopes in Infants Undergoing Neurosurgery: a Prospective Randomized Clinical TrialInfant ConditionsNCT04153370Kocaeli University60
Completed
Not Applicable
Comparison of Different Video Laryngoscopes in < 1 Year Old Undergoing Neurosurgical Operations: a Prospective Randomized StudyIntubation;DifficultNCT04153357Kocaeli University50
Completed
Not Applicable
Efficacy of Coopdech videolaryngoscope : Comparisons with a Macintosh laryngoscope and the Airway Scope in a manikin with difficult airwaysa manikin with difficult airwaysJPRN-UMIN000005715Dokkyo Medical University Koshigaya Hospital50
Completed
Not Applicable
Comparison of Different Video Laryngoscopes in a Manikin With Immobilized Cervical SpineTracheal IntubationNCT01210092University of Cologne25