MedPath

SOI Immediately vs Delayed

Not Applicable
Not yet recruiting
Conditions
Dental Implant-Abutment Design
Dental Implant
Interventions
Device: Delayed
Device: Immediately implant placement
Registration Number
NCT06286579
Lead Sponsor
Università degli Studi di Sassari
Brief Summary

The aim of this randomized controlled trial is to compare the clinical and radiographic of immediately loaded, immediate (post-extractive, test group) versus delayed (control group) implants with new SOI surface

Detailed Description

Not available

Recruitment & Eligibility

Status
NOT_YET_RECRUITING
Sex
All
Target Recruitment
70
Inclusion Criteria
  • Any patient with at least one hopeless tooth in the mandible or maxilla, located between premolars, with intact post extractive alveolus. The implants must to engage at least 3 (mandible) to 5 (maxilla) mm of residual native bone over the socket.
  • Patients with 18 years or older, and able to sign an informed consent.
  • Smokers will be included and categorized into: 1) non smokers; 2) moderate smokers (smoking up to 10 cigarettes/day); 3) heavy smokers (smoking more than 11 cigarettes/day). Heavy smokers will be excluded.
  • Biotype will be categorized in thin (≤1 mm), medium (>1 - <2 mm) or thick (≥2 mm).
Exclusion Criteria
  • General contraindications to implant surgery.
  • Patients irradiated in the head and neck area.
  • Immunosuppressed or immunocompromised patients.
  • Patients treated or under treatment with intravenous amino-bisphosphonates.
  • Patients with untreated periodontitis.
  • Patients with poor oral hygiene and motivation.
  • Uncontrolled diabetes.
  • Heavy smokers.
  • Pregnancy or nursing.
  • Substance abuser.
  • Psychiatric problems or unrealistic expectations.
  • Lack of opposite occluding dentition in the area intended for implant placement.
  • Patients with infection and or inflammation in the area intended for implant placement.
  • Patients participating in other studies, if the present protocol cannot be properly adhered to.
  • Patients referred only for implant placement and cannot be followed ant the treating centre.
  • Patients unable to be followed for 5 years

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
Delayed implant placementDelayedAtraumatic tooth extraction, after the site will be left to heal for 4 months, just grafting with A-Oss and suture, according to a socket preservation procedure. Four month later, implant will be place
Immediately implant placementImmediately implant placementAtraumatic tooth extraction and immediately placement of implant with a new surface
Primary Outcome Measures
NameTimeMethod
Number of implant failureUp to 5 years

defined as implant mobility and/or any infection dictating implant removal, and/or implant fracture and/or any other mechanical complication rendering the implant unusable. The stability of each individual implant will be measured by the local blinded outcome assessors manually tightening the screws with a torque of 30 Ncm at abutment connection, immediately loading, at 1,3 and 5 years after loading for the partial fixed prostheses. Once the single crowns will be cemented, their stability will be assessed by rocking the crown with the handles of two dental instruments.

Number of complicationsUp to 5 years

Technical (fracture of the framework and/or the veneering material, screw loosening, etc.) and/or biologic (pain, swelling, suppuration, peri-implantitis, etc.) complication will be considered.

Number of prosthesis failureUp to 5 years

Whether it will not be possible to place the prosthesis because of implant failure or a prosthesis that has to be remade for any reason.

Secondary Outcome Measures
NameTimeMethod
Rate of peri-implant marginal bone level changesAt 1,3 and 5 years

Peri-implant marginal bone level changes will be assessed on periapical radiographs took with the paralleling technique at implant placement, at initial loading, 1,3 and 5 years after loading. Ideally digital radiographs should be taken, otherwise radiographs on conventional films will be scanned into TIFF format with a 600 dpi resolution, and stored in a personal computer. Peri-implant marginal bone levels will be measured using the Scion Image (Scion Corporation, Frederick, MD, USA) software. The software will be calibrated for every single image using the known distance of the first two consecutive threads. Measurements of the mesial and distal bone crest level adjacent to each implant will be made to the nearest 0.01 mm. Reference points for the linear measurements will be: the coronal margin of the implant collar and the most coronal point of bone-to-implant contact. Bone levels will be measured.

Valuation of patient satisfactionAt 1,3 and 5 years

Patients will answer the following questions (separately for each implant):

1. Are you satisfied with the function of your implant-supported prostheses? Possible answers: yes absolutely, yes partly, not sure, not really, absolutely not.

2. Are you satisfied with the aesthetic outcome of your implant-supported prostheses? Possible answers: yes absolutely, yes partly, not sure, not really, absolutely not.

3. Would you undergo the same therapy again? Possible answers: "yes" or "no".

Number of PES score1,3 and 5 years

Esthetic evaluation of occlusal and vestibular pictures will take every years after definite loading was done following the pink esthetic score (PES). In brief, the PES score evaluates seven variables: mesial papilla, distal papilla, soft tissue level, soft tissue contour, alveolar process deficiencies, soft tissue color and texture. A 0-1-2 scoring system was used, 0 being the lowest and 2 being the highest value, with a maximum achievable score of 14 per dental unit.

Valuation of soft tissue thickness and amount of keratinized tissue1,3 and 5 years

The soft tissue biotype will be investigated by the same surgeon at the surgical procedures using a periodontal probe into the sulcus. Greater will be the thickness of the tissue, smaller will be transparency of the periodontal probe. The amount of keratinized tissue will be evaluated 1 year after surgical procedures using a periodontal probe. This outcome will be evaluated according to the distance from the gingival margin to the mucogingival junction

Rate of implant stability quotient (ISQ)Up to 5 years

ISQ was measured and recorded using the IS3 (Osstem), at implant placement, at implants exposure, at the impression time, and prosthetic loading.

Trial Locations

Locations (1)

Marco Tallarico

🇮🇹

Sassari, Italy

© Copyright 2025. All Rights Reserved by MedPath