跳至主要内容
临床试验/NCT05585060
NCT05585060招募中不适用

The Relevance and Consistency Study of Changes in End Expiratory Lung Impedence Measured by EIT and End Expiratory Lung Volume Measured by Passive Expiratory in Controlled Mechanical Ventilated Exacerbation COPD Patients

The First Affiliated Hospital of Guangzhou Medical University1 个研究点 分布在 1 个国家目标入组 10 人开始时间: 2022年9月13日最近更新:
适应症

试验速览

阶段
不适用
状态
招募中
发起方
入组人数
10
试验地点
1
主要终点
the changes of end expiratory lung volume

研究概览

简要总结

The pathophysiological characteristics of respiratory failure on exacerbation of chronic pulmonary obstructive disease are the rapid deteriorate of respiratory symptoms, combined with aggravated flow limitation, gas trapping, dynamic pulmonary hyperinflation (DPH), therefore the intrinsic PEEP (PEEPi) increases. It is worthwhile to explore bedside methods to quantify the changes in dynamic pulmonary hyperinflation to guide safe and effective mechanical ventilation in airflow limited patients.

详细描述

The study hypothesizes that the electrical impedence tomography (EIT) measured the changes of end expiratory lung impedence (△EELI) could accurately predict the changes of end expiratory lung volume (△EELV) measured by passive expiratory in controlled mechanical ventilated exacerbation COPD patients. The research intended to conduct a research to explore the relationship between △EELI and △EELV induced by external PEEP changes in ventilated exacerbation COPD patients.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
35 Years 至 80 Years(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • 2022.7-2023.1 exacerbation COPD invasive ventilated patients admitted to the first affiliated Guangzhou medical university; 35 to 80 years old; in stable condition judged by clinicians

排除标准

  • SpO2<88%; instable hemodynamic (MAP<65mmHg;Norepinephrine> 0.1ug/kg.min); pregnancy; 4 hour intravenous diuretics use before research; chest deformity and trauma, subpleural pulmonary bulla; implanted electronic devices(cardiac pacemaker, implantable cardioversion defibrillator,ect); tumour or other organ dysfunction; refuse to signature the informed consent

结局指标

主要结局

the changes of end expiratory lung volume

时间窗: 10 minutes

measured by EIT and IC maneuver

次要结局

  • intrinsic PEEP(10 minutes)

研究者

发起方
The First Affiliated Hospital of Guangzhou Medical University
申办方类型
Other
责任方
Principal Investigator
主要研究者

FuWei

Principal Investigator

The First Affiliated Hospital of Guangzhou Medical University

研究点 (1)

Loading locations...

相似试验