Acute Effects of a Heat-not-burn Tobacco Product on Pulmonary Function in Healthy Non Smokers.
- Conditions
- Heated TobaccoRespiratory FunctionTobacco Toxicity
- Interventions
- Other: IQOS
- Registration Number
- NCT03995329
- Lead Sponsor
- Aristotle University Of Thessaloniki
- Brief Summary
IQOS ("I-Quit-Ordinary-Smoking,") is a type of "heat-not-burn" (HNB) tobacco product. There is evidence of a growing number of young people who try IQOS as a 'safe' alternative of cigarette. The effect of the acute exposure to IQOS smoke on pulmonary function of healthy non smokers has not been studied extensively.
Objectives: Evaluation of the acute effects of IQOS on pulmonary function,exhaled CO, O2 Saturation, arterial pressure and heart rate.
Methods: Healthy non smokers, underwent exhaled CO measurement, spirometry including flows, volumes and diffusion capacity, and measurement of their respiratory resistances at 5, 10 and 20 Hz (R5Hz, R10Hz and R20Hz) with the use of an impulse oscillometry system (IOS) before and after the use of an IQOS. Additionally heart rate and arterial blood pressure were also measured.
- Detailed Description
All participants underwent pulmonary function tests (PFT) (MasterScreen PFT, Jaeger, Wurzburg, Germany) and total respiratory resistances measurement with an impulse oscillometry system (IOS)( (Viasys Jaeger MasterScreen IOS system).From the basic pulmonary measurements (flows and dynamic lung volumes), Forced Expiratory Volume in 1 second (FEV1), Forced Vital Capacity (FVC), Tiffenau index (FEV1/FVC, FEV1%), Peak Expiratory Flow (PEF), Maximal Expiratory Flow (MEF) at 25%, 50%, and 75% of vital capacity, Functional Residual Capacity (FRC), Total Lung Capacity (TLC), Residual Volume (RV), Diffusion Capacity (DLCO) were measured. Each manoeuvre was repeated for at least three technically acceptable forced expiratory flow curves in order to attain the best results. Respiratory impedance at 5 Hz (Z5Hz) and respiratory resistance at 5, 10, and 20 Hz (R5Hz, R10Hz, and R20Hz, respectively), reactance at 5, 10, and 20 Hz and resonant frequency were assessed with IOS. Heart rate, saturation of O2 (oxymetry) and arterial blood pressure were also measured. Exhaled CO measurement (piCO Smokerlyzer,Bedfont Scientific Ltd, Kent, U.K.) was performed After smoking heated tobacco (IQOS): 5 minutes after smoking IQOS , they repeated again PFTs, IOS, exhaled CO heart rate, saturation of O2 (oximetry) and arterial blood pressure measurements.
Recruitment & Eligibility
- Status
- COMPLETED
- Sex
- Male
- Target Recruitment
- 25
- Healthy male non smokers,
- Age 18-55 years
- receiving no medications
- no co morbidity -
- aged <18 years
- smokers or ex-smokers
- receiving any medications
- any co morbidity -
Study & Design
- Study Type
- INTERVENTIONAL
- Study Design
- SINGLE_GROUP
- Arm && Interventions
Group Intervention Description healthy non smokers IQOS Healthy non smokers males, aged 18-55years,receiving no medications Intervention: the use of an IQOS Examination of pulmonary function, exhaled CO, blood pressure, heart rate and O2 saturation immediatly after IQOS
- Primary Outcome Measures
Name Time Method Peak Expiratory Flow immediately (max 5 min) Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in: Peak Expiratory Flow (PEF), (liters/second )
Forced Expiratory Volume in 1 second immediately (max 5 min) Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in:Forced Expiratory Volume in 1 second (FEV1), (liters)
Tiffenau index immediately (max 5 min) Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in:
Tiffenau index (FEV1/FVC, FEV1%)Total Lung Capacity (TLC) immediately (max 5 min) Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in: Total Lung Capacity (TLC), (liters)
Forced Vital Capacity immediatly (max 5 min) Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in:Forced Vital Capacity (FVC), (liters)
Diffusion Capacity (DLCO) immediately (max 5 min) Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in: Diffusion Capacity (DLCO) ((mmol/min/kPa)
Total respiratory resistances immediately (max 5 min) Total respiratory resistances measurement with an impulse oscillometry system (IOS)( (Viasys Jaeger MasterScreen IOS system) prior to smoking heated tobacco IQOS and 5 minutes after smoking IQOS were performed. The changes in: respiratory resistance at 5 (R5Hz),10 Hz (R10Hz),20 Hz (R20Hz) (kPa/L/sec) were assessed
Functional Residual Capacity (FRC) immediately (max 5 min) Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in:Functional Residual Capacity (FRC), (liters)
Residual Volume (RV) immediately (max 5 min) Pulmonary function tests (PFT) prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in: Residual Volume (RV), (liters)
Oxygen Saturation immediately (max 5 min) Oxygen Saturation prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in Oxygen Saturation were measured by oximetry
Heart rate immediately (max 5 min) Heart rate prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in Heart rate were measured by oximetry
Respiratory impedance immediately (max 5 min) Total respiratory resistances measurement with an impulse oscillometry system (IOS)( (Viasys Jaeger MasterScreen IOS system) prior to smoking heated tobacco IQOS and 5 minutes after smoking IQOS were performed. The changes in: Respiratory impedance at 5 Hz (Z5Hz) (kPa/L/sec) were assessed
Arterial Blood Pressure immediately (max 5 min) Arterial Blood Pressure prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in Arterial Blood Pressure were measured (mmHg)
Exhaled CO immediately (max 5 min) Exhaled CO prior to smoking heated tobacco IQOS and 5 minutes after IQOS. The changes in Exhaled CO were measured by (piCO Smokerlyzer) (ppm)
- Secondary Outcome Measures
Name Time Method
Trial Locations
- Locations (2)
G Papanicolaou Hospital
🇬🇷ThessalonÃki, Thessaloniki, Greece
Respiratory Failure Unit, G Papanikolaou Hospital, Aristotle Unioversity of Thessaloniki
🇬🇷ThessalonÃki, Greece