Brief Summary

This study aims to evaluate brain death with optical probes. The changes of hemodynamic parameters including oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) were detected by near infrared spectroscopy probes attached on the forehead of patients. A multiple-phase protocol at varied fraction of inspired O2 were utilized during the assessment.

Detailed Description

Brain death is an irreversible loss of all brain functions, and the assessment is crucial for organ supply for transplantation. The noninvasive, sensitive, universally available and timely ancillary method to assess brain death has not been established. This study aims to evaluate brain death with optical probes. The changes of hemodynamic parameters including oxyhemoglobin (HbO2) and deoxyhemoglobin (Hb) were detected by near infrared spectroscopy probes attached on the forehead of patients. A multiple-phase protocol at varied fraction of inspired O2 were utilized during the assessment. The concentration changes ratios of oxyhemoglobin to deoxyhemoglobin (Δ\[HbO2\]/Δ\[Hb\]) in the cerebral cortex of brain-dead patients were significantly higher than those of healthy subjects.

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
80
Inclusion Criteria
  • Patients who have had brain death or serious brain trauma.
  • Healthy people who are interested in optical assessment of hemodynamic parameters
Exclusion Criteria
  • Patients who are in pregnancy or have plan to conception.

  • Patients who have vertebra surgery or have plan of surgery.

  • Patients who are inappropriate to join this trial judged by the radiologists or specialists.

    • AIDS, Active Hepatitis, Tuberculosis, Syphilis
    • Patients who regularly take anticoagulants, antiplatelet drugs

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Healthy people for HLH OxygenOxygen supply of high-low-high procedureHealthy people were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of high-low-high procedure. During the procedures, the Δ\[Hb\] and Δ\[HbO2\] time courses were collected by Optical monitor for hemodynamic parameter.
Brain death patients for HLH OxygenOxygen supply of high-low-high procedureBrain-dead patients were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of high-low-high procedure. During the procedures, the Δ\[Hb\] and Δ\[HbO2\] time courses were collected by Optical monitor for hemodynamic parameter.
Healthy people for LHL OxygenOptical monitor for hemodynamic parameter.Healthy people were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of low-high-low procedure. During the procedures, the Δ\[Hb\] and Δ\[HbO2\] time courses were collected by Optical monitor for hemodynamic parameter.
Brain death patients for LHL OxygenOxygen supply of low-high-low procedureBrain-dead patients were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of low-high-low procedure. During the procedures, the Δ\[Hb\] and Δ\[HbO2\] time courses were collected by Optical monitor for hemodynamic parameter.
Brain death patients for LHL OxygenOptical monitor for hemodynamic parameter.Brain-dead patients were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of low-high-low procedure. During the procedures, the Δ\[Hb\] and Δ\[HbO2\] time courses were collected by Optical monitor for hemodynamic parameter.
Healthy people for LHL OxygenOxygen supply of low-high-low procedureHealthy people were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of low-high-low procedure. During the procedures, the Δ\[Hb\] and Δ\[HbO2\] time courses were collected by Optical monitor for hemodynamic parameter.
Brain death patients for HLH OxygenOptical monitor for hemodynamic parameter.Brain-dead patients were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of high-low-high procedure. During the procedures, the Δ\[Hb\] and Δ\[HbO2\] time courses were collected by Optical monitor for hemodynamic parameter.
Healthy people for HLH OxygenOptical monitor for hemodynamic parameter.Healthy people were supplied with oxygen at varied FIO2 at medical premised range.The protocol is Oxygen supply of high-low-high procedure. During the procedures, the Δ\[Hb\] and Δ\[HbO2\] time courses were collected by Optical monitor for hemodynamic parameter.
Primary Outcome Measures
NameTimeMethod
Δ[HbO2]1 day during the whole experiment

The changes of oxyhemoglobin concentrations in prefrontal cortex.

Δ[Hb]1 day during the whole experiment

The changes of deoxyhemoglobin concentrations in prefrontal cortex.

Secondary Outcome Measures
NameTimeMethod
Heart rate1 day during the whole experiment

Heart rate of patient recorded by bed-side physiological monitor.

Blood pressure1 day during the whole experiment

Blood pressure of patient recorded by bed-side physiological monitor.