Image Quality and Radiation Dose Associated With Cardiac Scans in Modern CT Scanners

Conditions
Coronary Artery Disease
Interventions
Diagnostic Test: Cardiac CTA on a photon-counting detector CT (PCD-CT)
Diagnostic Test: Cardiac CTA on a regular CT with Energy-Integrating Detector (EID-CT)
Registration Number
NCT05245149
Lead Sponsor
University Hospital Augsburg
Brief Summary

The main objective of this study is to evaluate the dose efficiency of coronary CT angiography (CTA) using a photon counting detector CT (PCD-CT) with the dose efficiency of coronary CT angiography of prior CT generations. 100 patients with a clinical indication for coronary CT angiography will be prospectively enrolled and undergo coronary CTA on a PCD-CT. For comparison, a matched retrospective cohort of 100 patients will be created who had undergone on a prior scanner generation (retrospective cohort).

Detailed Description

Not available

Recruitment & Eligibility

Status
UNKNOWN
Sex
All
Target Recruitment
200
Inclusion Criteria
  • indication for coronary CTA confirmed by board-certified radiologist ('justified indication' according to German/European radiation protection law) AND
  • patient (is able to give informed consent and) has given informed consent.
Exclusion Criteria
  • contraindications to (iodine based) iv contrast material: known allergy to iodine-based iv contrast, acute or high-grade chronic kidney insufficiency with an estimated glomerular filtration rate < 30 ml/min/1.73 m², latent or manifest hyperthyroidism
  • known or suspected pregnancy
  • lactating mothers

Study & Design

Study Type
OBSERVATIONAL
Study Design
Not specified
Arm && Interventions
GroupInterventionDescription
Prospective CohortCardiac CTA on a photon-counting detector CT (PCD-CT)Patients with a clinical indication for coronary CT angiography will undergo this scan on a photon counting detector CT (PCD-CT).
Retrospective CohortCardiac CTA on a regular CT with Energy-Integrating Detector (EID-CT)For comparison, a matched retrospective cohort will be created of patients who had undergone coronary CT angiography on prior CT scanner generations (with energy-integrating detector CT, EID-CT)
Primary Outcome Measures
NameTimeMethod
Intraluminal Enhancement of Coronary Arteries1 year

measured on thin-slice reconstructions, in Hounsfield units

Image Noise1 year

measured on thin-slice reconstructions, in Hounsfield units

Dose-Length Product (DLP)1 year

Integrative descriptor for the x-ray dose applied during acquisition; can be read out from the scan protocol.

Overall subjective image quality1 year

as assessed by board-certified and speciality-trained radiologists on a 5-point Likert scale

Secondary Outcome Measures
NameTimeMethod
Diagnostic Accuracy of Coronary Artery Stenosis Assessment in Comparison with invasive catheter angiography1 year

Comparison in the subgroups of patients who als undergo invasive catheter angiography