Image Quality and Radiation Dose Associated With Cardiac Scans in Modern CT Scanners
- Conditions
- Coronary Artery Disease
- Interventions
- Diagnostic Test: Cardiac CTA on a photon-counting detector CT (PCD-CT)Diagnostic Test: Cardiac CTA on a regular CT with Energy-Integrating Detector (EID-CT)
- Registration Number
- NCT05245149
- Lead Sponsor
- University Hospital Augsburg
- Brief Summary
The main objective of this study is to evaluate the dose efficiency of coronary CT angiography (CTA) using a photon counting detector CT (PCD-CT) with the dose efficiency of coronary CT angiography of prior CT generations. 100 patients with a clinical indication for coronary CT angiography will be prospectively enrolled and undergo coronary CTA on a PCD-CT. For comparison, a matched retrospective cohort of 100 patients will be created who had undergone on a prior scanner generation (retrospective cohort).
- Detailed Description
Not available
Recruitment & Eligibility
- Status
- UNKNOWN
- Sex
- All
- Target Recruitment
- 200
- indication for coronary CTA confirmed by board-certified radiologist ('justified indication' according to German/European radiation protection law) AND
- patient (is able to give informed consent and) has given informed consent.
- contraindications to (iodine based) iv contrast material: known allergy to iodine-based iv contrast, acute or high-grade chronic kidney insufficiency with an estimated glomerular filtration rate < 30 ml/min/1.73 m², latent or manifest hyperthyroidism
- known or suspected pregnancy
- lactating mothers
Study & Design
- Study Type
- OBSERVATIONAL
- Study Design
- Not specified
- Arm && Interventions
Group Intervention Description Prospective Cohort Cardiac CTA on a photon-counting detector CT (PCD-CT) Patients with a clinical indication for coronary CT angiography will undergo this scan on a photon counting detector CT (PCD-CT). Retrospective Cohort Cardiac CTA on a regular CT with Energy-Integrating Detector (EID-CT) For comparison, a matched retrospective cohort will be created of patients who had undergone coronary CT angiography on prior CT scanner generations (with energy-integrating detector CT, EID-CT)
- Primary Outcome Measures
Name Time Method Intraluminal Enhancement of Coronary Arteries 1 year measured on thin-slice reconstructions, in Hounsfield units
Image Noise 1 year measured on thin-slice reconstructions, in Hounsfield units
Dose-Length Product (DLP) 1 year Integrative descriptor for the x-ray dose applied during acquisition; can be read out from the scan protocol.
Overall subjective image quality 1 year as assessed by board-certified and speciality-trained radiologists on a 5-point Likert scale
- Secondary Outcome Measures
Name Time Method Diagnostic Accuracy of Coronary Artery Stenosis Assessment in Comparison with invasive catheter angiography 1 year Comparison in the subgroups of patients who als undergo invasive catheter angiography