MedPath

Comparison of Metal on Metal Total Hip Arthroplasty and Metal on Metal Total Hip Resurfacing.

Phase 4
Completed
Conditions
Arthroplasty
Replacement
Hip
Interventions
Device: HR
Device: THA
Registration Number
NCT04516239
Lead Sponsor
Ciusss de L'Est de l'Île de Montréal
Brief Summary

The goal of this double-blind prospective randomized study is to compare subjective outcome measures and gait parameters between conventional THA using large diameter femoral heads and total hip resurfacing

Detailed Description

In the early 1960's Sir John Charnley revolutionized total hip arthroplasty (THA) with the introduction of polyethylene as a bearing surface. This innovation allowed THA to become a very successful procedure to treat degeneration of the hip joint, with excellent long term clinical outcome and patient satisfaction.

However, this technique requires sacrifice of the whole femoral head and part of the neck. This bone will not be available for future revision surgery, which seems inevitable in the younger patient. THA does not always allow precise reconstitution of normal hip biomechanics. The femoral canal is also violated, fat and cement embolism can occur and thrombogenic material is released in the bloodstream. Postoperatively the femoral stem can cause thigh pain, proximal stress shielding, and periprosthetic fracture may occur . Finally the use of a 28 millimeter non anatomic femoral head during conventional THA increases the risk of hip impingement and dislocation while limiting hip range of motion.

There is renewed interest in the concept of hip resurfacing and the use of large diameter femoral heads in total hip arthroplasty, since both these options recreate more optimal hip biomechanics. Total hip resurfacing is less invasive than conventional THA using a femoral stem and allows restoration of normal hip anatomy. Additionally, compared to conventional THA, hip resurfacing has the following advantages: preservation of the femoral head and neck, better hip stability, improved hip biomechanics (leg length, offset) and possibly better proprioception. Since the femoral canal is not violated, there is less risk of residual thigh pain, and patients probably have the sensation of a more normal feeling joint.

As for conventional THA with large diameter femoral heads, the use of a near anatomic head size (compared to the small 28mm diameter head use with conventional THA) restores normal stability, helps reduce the incidence of impingement and increases range of motion to a greater extent than hip resurfacing, and might improve proprioception as well. The investigators believe these advantages will have a positive influence on clinical function and gait pattern compared to conventional THA.

Gait analysis has demonstrated that gait pattern is modified after THA and patients do not recover normal gait. Kinematics analysis further showed that abnormal gait pattern is not only observed in the operated hip but also in other articulations, including the contra lateral limb. Walking kinetics are affected to some extent, especially the force generated by the lower limb and synchronization of muscle activity. Finally a subjective feeling of an abnormal hip function may still persists after THA.

The goal of this double-blind prospective randomized study is to compare subjective outcome measures and gait parameters between conventional THA using large diameter femoral heads and total hip resurfacing

Recruitment & Eligibility

Status
COMPLETED
Sex
All
Target Recruitment
48
Inclusion Criteria
  1. Patient with degenerative disease of the hip in need for total hip or total hip resurfacing arthroplasty
  2. Patient who understands the study protocol and willing to comply with the planned clinical follow-up
  3. Patient can give informed consent
Exclusion Criteria
  1. Age older than 65 years old or younger than 18 years old
  2. Charnley class B (both hip diseased) or C (polyarticular disease) patients
  3. Spinal or lower limb disease other than the degenerated hip that could influence gait and walking performance
  4. Neuromuscular disorder
  5. Known or suspected metal allergy
  6. Pregnancy
  7. Renal insufficiency
  8. Known or suspected osteopenia or osteoporosis of the hip

Study & Design

Study Type
INTERVENTIONAL
Study Design
PARALLEL
Arm && Interventions
GroupInterventionDescription
HRHRmetal-on-metalhip resurfacing
LDH THATHAlarge diameter head total hip arthroplasty
Primary Outcome Measures
NameTimeMethod
Implant revisionsPreoperative to 15 years

Implant revisions rate will be compared between groups.

Reasons of revisionsPreoperative to 15 years

Reasons of revisions will be categorized and compared between groups.

Adverse eventsPreoperative to 15 years

Adverse events will be categorized and compared between groups.

Secondary Outcome Measures
NameTimeMethod
Patient reported outcome measures (PROMs) : WomacPreoperative to 15 years

Womac score will be compared between groupsScore and Patient's Joint Perception.

Patient reported outcome measures (PROMs) : UCLA activityPreoperative to 15 years

The UCLA activity score will be compared between groups.

Patient reported outcome measures (PROMs) : Forgotten JointPreoperative to 15 years

Forgotten Joint score will be compared between groups.

Whole blood chromium metal ions levelsPreoperative to 15 years

Whole blood chromium metal ion measurements will be compared between groups for participants without other bodily metallic implants or revised implants.

Whole blood cobalt metal ions levelsPreoperative to 15 years

Whole blood cobalt metal ion measurements will be compared between groups for participants without other bodily metallic implants or revised implants.

Radiological evaluation of femoral stem looseningPreoperative to 15 years

Signs of definite femoral stem loosening included continuous lucent lines \> 2 mm, stem fracture, subsidence \> 5 mm, or a change in component angulation \>5° will be compared between groups.

Radiological evaluation of acetabular looseningPreoperative to 15 years

Signs of definite acetabular loosening presented as continuous radiolucency \> 2 mm, component migration \> 3 mm or angulation change \>5° will be compared between groups.

Radiological evaluation of heterotopic ossificationPreoperative to 15 years

Signs of heterotopic ossification grade, estimated according to the Brooker classification, will be compared between groups.

© Copyright 2025. All Rights Reserved by MedPath