跳至主要内容
临床试验/NCT01017744
NCT01017744已完成3 期

Respiratory Mechanical Effects of Sevoflurane Administered With the Anesthetic Conserving Device in Pressure Support Ventilation

University Hospital, Clermont-Ferrand2 个研究点 分布在 1 个国家目标入组 15 人开始时间: 2009年11月1日最近更新:
适应症

试验速览

阶段
3 期
状态
已完成
发起方
入组人数
15
试验地点
2
主要终点
Work Of Breathing (WOB) measured during the last 5 minutes of the 20 minutes period of each treatment

研究概览

简要总结

Sevoflurane inhalational anesthetic has got pulmonary effects such as bronchodilatation. These effects could be of interest in intensive care patients ventilated in pressure support ventilation mode. The purpose of this study is to evaluate mechanical respiratory effects of sevoflurane administered through a new specific heat and moister exchanger called the Anesthetic Conserving Device (AnaConDa®) in pressure support ventilation in intensive care patients. In fact, dead space and resistance generated by the device could cancel and even deteriorate the potential positive effects of sevoflurane on ventilation.

详细描述

Pharmacological sedation is often necessary in mechanical ventilated intubated patient. Since a little time, sevoflurane can be used in the intensive care unit via a specific heat and moister exchanger called the Anesthetic Conserving Device (AnaConDa®, SedanaMedical AB, Uppsala, Sweden) placed between the Y piece of the ventilatory circuit and the endotracheal tube. Sevoflurane is known to have ventilatory interesting effects such as bronchodilatation that can be useful in the treatment of severe asthma. These effects could be of interest in the intensive care ventilated patients. On the other hand, the AnaConDa® device could have negative influence on ventilatory mechanics caused by the increased dead space and the resistance to air flow. This negative effect with worsening of work of breathing (WOB) was demonstrated with classic heat and moister exchanger compared to heated humidifiers in pressure support ventilation (PSV). In this way, we would like to study the mechanical effects of the sevoflurane administered with the AnaConDa® compared to a classic management with a heated humidifier and sedation with intravenous remifentanil in PSV consecutive intensive care patients.

研究设计

研究类型
Interventional
分配方式
Non Randomized
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Adults ICU patients who are no more in acute state, intubated and ventilated in pressure support ventilation with intravenous sedation by remifentanil, with light sedation (RASS -1 to -2).

排除标准

  • Respiratory distress.

结局指标

主要结局

Work Of Breathing (WOB) measured during the last 5 minutes of the 20 minutes period of each treatment

时间窗: during the last 5 minutes of the 20 minutes period of each treatment

次要结局

  • Intrinsic positive end expiratory pressure (PEEPi), occlusion pressure (P0,1), peak expiratory resistance, respiratory rate, tidal volume, minute ventilation, death space volume.(in PSV consecutive intensive care patients)