跳至主要内容
临床试验/NCT02395757
NCT02395757已完成不适用

Assessment Using Microperimetry of the Risk of a Fellow Eye Progressing From Stage 3 to Stage 4 (AREDS Classification) Age-related Macular Degeneration (AMD)

Hospices Civils de Lyon2 个研究点 分布在 1 个国家目标入组 182 人开始时间: 2015年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
入组人数
182
试验地点
2
主要终点
The sensitivity of the microperimetric parameter(s) and combination(s) of parameters according to patient status at final assessment.

研究概览

简要总结

Age-related macular degeneration (AMD) is an acquired retinal pathology affecting the central region of the retina responsible for discrimination between high spatial frequencies (reading), colour vision and the central visual field. The loss of visual acuity which occurs with the onset of AMD significantly affects patients' quality of life. In developed countries, AMD is the leading cause of vision impairment for people aged over 50 years. Its prevalence in Europe in people aged over 65 years is 3.3%. In France, around 2 million people suffer from this disease.

In the first stage of the disease it is known as age-related maculopathy (ARM). This early form of the disease can develop into intermediate AMD (stage 3 of the AREDS classification) and then advanced AMD (stage 4 AREDS), which can be atrophic or exudative. In cases of exudative AMD, the intravitreal administration of anti-VEGF drugs can limit the disease's progression.

It is therefore vital to adopt a strategy to assess the stage of the disease and provide the appropriate care management at the earliest possible stage. This is even more important for patients with advanced AMD in one eye and intermediate AMD in the fellow eye, as the risk of the fellow eye progressing to the advanced stage within 5 years is between 35% and 53%.

Microperimetry is a promising new diagnostic method which combines measurements of light sensitivity, loss of fixation and the anatomy of the retina. It offers a new approach to the functional assessment of retinal damage in patients with AMD, as it precisely correlates anatomical and functional modifications by measuring the loss of sensitivity and macular fixation. It has been shown that the more advanced the patient's AMD is, the further the parameters measured by microperimetry are from the norm.

The investigators want to assess the MAIA™ as a means of screening for AMD progression in patients with a high risk of progressing to a more advanced stage (patients presenting one eye with advanced AMD and a fellow eye with stage 3 AMD according to the AREDS classification). The research hypothesis for our proposed study is that the parameters measured using microperimetry will already show abnormal results in the study eye prior to progressing to a more advanced stage of the disease. The use of these microperimetric parameters as predictor of progression would therefore make it possible to screen eyes likely to develop from intermediate to advanced AMD at an earlier stage, and subsequently provide patients who need it with earlier follow-up, preventive treatment or adapted, personalized rehabilitation as appropriate.

研究设计

研究类型
Interventional
分配方式
Na
干预模型
Single Group
主要目的
Diagnostic
盲法
None

入排标准

年龄范围
50 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Patient aged 50 years or over;
  • Patient who has given their free, informed, signed consent;
  • Patient with a French social security number or equivalent cover;
  • Patient presenting one eye with stage 4 AMD (according to the AREDS classification), and drusen in the fellow eye (study eye) with at least one drusen with a diameter of over 125 microns and/or extra- foveal atrophy (stage 3 AREDS);
  • Patient who is willing and able to attend all the clinical appointments required for the study and complete all the related procedures.

排除标准

  • Patient aged under 50 years;
  • Patient who refuses to take part in the study;
  • Woman who is pregnant or breastfeeding;
  • Protected adult as set out in French law (French Public Health Law);
  • Patient presenting a study eye with stage 1, 2 or 4 AMD (AREDS classification);
  • Patient presenting another maculopathy in the study eye;
  • Area alteration (cornea, lens, vitreous humour) which makes it impossible to carry out and interpret the microperimetry correctly;
  • Patient due to undergo cataract surgery in the study eye during the 2-year study period;
  • Patients who cannot be followed up for the full 2 years;
  • Patients participating simultaneously in other studies which may interfere with the study results (in either eye).

结局指标

主要结局

The sensitivity of the microperimetric parameter(s) and combination(s) of parameters according to patient status at final assessment.

时间窗: 24 months

The sensitivity of the microperimetry diagnostic tool will be measured by the ratio between the number of patients presenting both positive microperimetric parameters and advanced AMD (stage 4); and the total number of patients with advanced AMD diagnosed at final assessment.

次要结局

  • The positive predictive value of the microperimetric parameter or combination of parameters with the highest level of sensitivity(24 months after inclusion)
  • The specificity of the microperimetric parameter or combination of parameters with the highest level of sensitivity(24 months after inclusion)
  • The sensitivity of the microperimetric parameters associated with the parameters from other ophthalmological examinations.(24 months after inclusion)
  • The negative predictive value of the microperimetric parameter or combination of parameters with the highest level of sensitivity(24 months after inclusion)
  • The specificity of the microperimetric parameters associated with the parameters from other ophthalmological examinations.(24 months after inclusion)
  • The sensitivity of the microperimetric parameters or combinations of parameters for the sub-group of eyes presenting reticular pseudodrusen at inclusion.(24 months after inclusion)
  • The specificity of the microperimetric parameters or combinations of parameters for the sub-group of eyes presenting reticular pseudodrusen at inclusion.(24 months after inclusion)

研究者

申办方类型
Other
责任方
Sponsor

研究点 (2)

Loading locations...

相似试验