Ultrasonography for Prediction of Extubation Success: a Holistic Approach

Amsterdam UMC, location VUmc0 个研究点目标入组 83 人开始时间: 2016年9月1日最近更新:
适应症

试验速览

阶段
不适用
状态
已完成
发起方
入组人数
83
主要终点
Area under the Curve

研究概览

简要总结

This study evaluates thickening fraction alone and together with other ultrasound parameters of heart and lungs as predictors for extubation outcome

详细描述

Weaning patients in the intensive care unit (ICU) from the mechanical ventilator is a critical period and accounts for 40% of the duration of mechanical ventilation itself. Weaning failure includes failing the initial spontaneous breathing trial (SBT) and patients with extubation failure. Extubation failure is defined as reintubation or need for rescue non-invasive ventilation within 48 hours following extubation. Patients failing extubation experience increased time spent on the mechanical ventilator and even increased mortality rates. Given these risks, predicting readiness for extubation is of key importance in the ICU.

Studies have shown, that US is a viable tool for routine use due to its bedside availability and non-invasiveness, while still maintaining excellent predictive values for its respective applications. For this reason, over the past years, critical care ultrasonography (US) has become an important part of routine bedside assessment Lately, the diaphragm has been studied extensively, due to its strong role in sustaining spontaneous breathing. Especially predicting extubation outcomes

has become a great field of interest and different studies have been conducted on this topic. Currently, indices such as diaphragm thickening (Tdi), diaphragm thickness (Tdi%) and diaphragm motion are the most frequently used parameters. Of these, thickening fraction seems to be the most promising to predict successful extubation.

However, all of the studies conducted, solely looked at diaphragm function and compared them to current standards such as the rapid shallow breathing index, while disregarding other factors strongly correlated to extubation failure, e.g. respiratory and cardiac function, as proposed by Mayo et al. Taking heart and lung function into account as well seems to be an interesting approach, because additional measurements could possibly improve predictive value while putting no further burden on the patient. Furthermore, both heart and lungs can be assessed quickly and easily by ultrasound. Cardiac parameters that are potentially useful are left ventricular function, mitral diastolic inflow and cardiac output. Regarding the lungs, pleural effusion is associated with rate of success for extubation. Effusion is detected easily and recent studies have shown, that in an ICU setting a simple 8 region protocol is sufficient to detect extra vascular lung water.

The investigators hypothesise that a holistic US approach, including measurements of heart, lungs and diaphragm, will be superior to the core diagnostic parameters of the diaphragm in predicting extubation success in mechanically ventilated critical care patients.

研究设计

研究类型
Observational
观察模型
Cohort
时间视角
Prospective

入排标准

年龄范围
18 Years 至 —(Adult, Older Adult)
性别
All
接受健康志愿者

入选标准

  • Ventilated for > 72 hours
  • Passed spontaneous breathing trial

排除标准

  • Planned NIV
  • Palliative Extubation
  • Tracheostomy
  • Paraplegia above Th 8

结局指标

主要结局

Area under the Curve

时间窗: 48 hours

Area under the receiver operator curve

Specificity

时间窗: 48 hours

Specificity of thickening fraction for extubation failure

Sensitivity

时间窗: 48 hours

Sensitivity of thickening fraction for extubation failure

Correlation of ultrasound variables with extubation outcome

时间窗: 48 hours

Correlation of ultrasound variables with extubation outcome through (logistic)regression analysis.