Comparison of Alignment Achieved Using the VELYS Robotic-Assisted Solution Versus Manual Instrumentation in Total Knee Arthroplasty: A Prospective, Non-Randomized Multi-Center Post-market Clinical Investigation
试验速览
- 阶段
- 不适用
- 状态
- 已完成
- 入组人数
- 200
- 试验地点
- 10
- 主要终点
- Accuracy of the Hip-Knee-Ankle Angle (HKA) Measured on Long-leg X-rays at 12 Weeks.
研究概览
简要总结
The purpose of this post-market research study is to gather clinical and radiographic (X-ray) information about total knee replacement surgeries completed with the VELYS Robotic-Assisted Solution and with standard manual instrumentation. The VELYS Robotic-Assisted Solution helps the surgeon to plan bone cuts and then accurately achieve the planned cuts during the total knee replacement surgery. The study aims to compare how well the VELYS Robotic-Assisted system enables the surgeon to position the implants exactly as planned compared to manual instrumentation.
研究设计
- 研究类型
- Interventional
- 分配方式
- Non Randomized
- 干预模型
- Sequential
- 主要目的
- Treatment
- 盲法
- Single (Outcomes Assessor)
盲法说明
Quantitative analysis of the X-rays will be conducted by a third party who will be blinded to the treatment group.
入排标准
- 年龄范围
- 22 Years 至 85 Years(Adult, Older Adult)
- 性别
- All
- 接受健康志愿者
- 否
入选标准
- •Subject is male or female and between the ages of 22 and 85 years at the time of consent, inclusive.
- •Subject has a severely painful and/or severely disabled joint resulting from osteoarthritis, post-traumatic arthritis or rheumatoid arthritis and in the opinion of the Investigator, is a suitable candidate for primary TKA using the devices described in this CIP with either resurfaced or non-resurfaced patellae.
- •Subject that is willing to give voluntary, written informed consent to participate in this clinical investigation and authorize the transfer of his/her information to the Sponsor
- •Subject is currently not permanently bedridden, as determined by the Investigator
- •Subject, in the opinion of the Investigator, is able to understand this clinical investigation and is willing and able to perform all study procedures and follow-up visits and co-operate with investigational procedures.
- •Subject is able to read and comprehend the Informed Consent Document as well as complete the required PROs in English.
- •Subject's pre-operative alignment is such that (in the opinion of the Investigator) it is appropriate for it to be adjusted to mechanical long leg alignment during surgery.
排除标准
- •The Subject is a woman who is pregnant or lactating.
- •Contralateral knee has already been enrolled in this study.
- •Subject had a contralateral amputation.
- •Previous partial knee replacement (unicompartmental, bicompartamental or patellofemoral joint replacement), patellectomy, high tibial osteotomy or primary TKA in affected knee.
- •Subject has an active local or systemic infection
- •Subject has loss of bone or musculature, osteoporosis, neuromuscular compromise or vascular deficiency in the affected limb in sufficient degree to render the procedure unjustifiable in the opinion of the Investigator (e.g. absence of musculo-ligamentous supporting structures, joint neuropathy)
- •Subject has severe instability secondary to advanced loss of osteochondral structure or the absence of collateral ligament integrity.
- •Subject has participated in a clinical investigation with an investigational product (drug or device) in the last three (3) months.
- •Subject is currently involved in any personal injury litigation, medical-legal or worker's compensation claims.
结局指标
主要结局
Accuracy of the Hip-Knee-Ankle Angle (HKA) Measured on Long-leg X-rays at 12 Weeks.
时间窗: 12 weeks
The primary objective of this clinical investigation is to evaluate whether the accuracy to plan of the long leg alignment achieved with VELYS Robotic-Assisted Solution is non-inferior to the accuracy to plan of the long leg alignment achieved with the manual ATTUNE Intuition instrumentation. This will be assessed by measuring the Hip-Knee-Ankle angle (HKA) on long-leg X-rays taken at 12 weeks and comparing to the planned HKA. A smaller number represents improved accuracy and a better outcome.
次要结局
- Accuracy of the Distal Femoral Varus-valgus Angle Measured on Long Leg X-rays at 12 Weeks.(12 weeks)
- Accuracy of the Proximal Tibial Varus-valgus Angle Measured on Long-leg X-rays at 12 Weeks(12 weeks)
- Accuracy of Femoral Component Flexion Angle Measured on Lateral X-rays at 12 Weeks(12 weeks)
- Accuracy of the Tibial Slope Angle Measured on Lateral X-rays at 12 Weeks(12 weeks)
- Type and Frequency of Adverse Events(12 weeks, 1 year)
- Soft Tissue Damage(Day of operation (intraoperative))